Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1998 Jan;93(1):92-8.
doi: 10.1111/j.1572-0241.1998.092_c.x.

Reproducibility and simplification of 13C-octanoic acid breath test for gastric emptying of solids

Affiliations
Comparative Study

Reproducibility and simplification of 13C-octanoic acid breath test for gastric emptying of solids

M G Choi et al. Am J Gastroenterol. 1998 Jan.

Abstract

Objective: The accuracy of the 13C-octanoic acid breath test is enhanced by breath sampling over 6 h rather than 4 h, but this increases the cost of the test. Our aim was to validate a less costly but accurate sequence of breath sampling for measuring gastric emptying of solids.

Methods: We performed the 13C-octanoic acid breath test and tested its reproducibility relative to simultaneous scintigraphy in 30 healthy volunteers.

Results: There was a significant but weak correlation between t1/2 measured by the two tests (rs = 0.54, p < 0.005), but not between the duration of the lag phase. The differences in the t1/2 measurements between the tests were different between subjects but were highly reproducible within subjects. Within- and between-subject variations of measurements of gastric emptying with the 13C-octanoic acid breath test were not significantly different from the variations observed with scintigraphy. A subset of 11 breath samples collected over 6 h (24 samples) predicted (r2 > 0.95) the variables characterizing the cumulative appearance of 13CO2 in breath; these samples were at 35, 50, 95, 110, 140, 155, 215, 245, 260, 290, and 335 min. The accuracy of this subset of sampling times was confirmed in a separate set of breath test samples over 6 h from the same 30 subjects.

Conclusions: The 13C-octanoic acid breath test for gastric emptying of solids is as reproducible as scintigraphy. A subset of 11 sampling times provides sufficient information to characterize the whole breath-test curve, but the sampling period should be extended to 6 h after dosing.

PubMed Disclaimer

Publication types

LinkOut - more resources