Abstract
A portable ultrasound to determine bladder volume, the BladderScan 2500, was compared to transurethral catheterization in 72 women. Most measurements were made after voiding. Volumes measured by catheterization were 17 ml greater than those measured by ultrasound, which was not clinically significant. The BladderScan technique does not carry the risk of urinary tract infection or patient trauma, and patient dignity is preserved, while accurately determining urinary volume.
Similar articles
-
[Determination of residual urine volume using a portable ultrasound apparatus in a rehabilitation center for spinal lesions].Med Arh. 2003;57(3):165-7. Med Arh. 2003. PMID: 12858657 Croatian.
-
Accuracy of post-void residual urine volume measurement using a portable ultrasound bladder scanner with real-time pre-scan imaging.Neurourol Urodyn. 2011 Mar;30(3):335-8. doi: 10.1002/nau.20977. Neurourol Urodyn. 2011. PMID: 20658544
-
Diagnosis of Postoperative Urinary Retention Using a Simplified Ultrasound Bladder Measurement.Anesth Analg. 2015 May;120(5):1033-1038. doi: 10.1213/ANE.0000000000000595. Anesth Analg. 2015. PMID: 25642660 Clinical Trial.
-
Cystic pelvic pathology presenting as falsely elevated post-void residual urine measured by portable ultrasound bladder scanning: report of 3 cases and review of the literature.Urology. 2000 Apr;55(4):590. doi: 10.1016/s0090-4295(99)00565-8. Urology. 2000. PMID: 10754180 Review.
-
[Efficacy and problems of bladder volume measurement using portable three dimensional ultrasound scanning device--in particular, on measuring bladder volume lower than 100ml].Nihon Hinyokika Gakkai Zasshi. 2005 Sep;96(6):601-9. doi: 10.5980/jpnjurol1989.96.601. Nihon Hinyokika Gakkai Zasshi. 2005. PMID: 16218402 Review. Japanese.
Cited by
-
Three-dimensional bladder ultrasonography with the BladderScan® overestimates post void residual one week after delivery.Eur J Obstet Gynecol Reprod Biol X. 2019 May 14;3:100030. doi: 10.1016/j.eurox.2019.100030. eCollection 2019 Jul. Eur J Obstet Gynecol Reprod Biol X. 2019. PMID: 31403119 Free PMC article.
-
Sonographic assessment of postvoid residual urine volumes in patients with benign prostatic hyperplasia.J Natl Med Assoc. 2004 Feb;96(2):234-9. J Natl Med Assoc. 2004. PMID: 14977284 Free PMC article.
-
Revolutionizing Bladder Health: Artificial-Intelligence-Powered Automatic Measurement of Bladder Volume Using Two-Dimensional Ultrasound.Diagnostics (Basel). 2024 Aug 22;14(16):1829. doi: 10.3390/diagnostics14161829. Diagnostics (Basel). 2024. PMID: 39202317 Free PMC article.
-
Is Doppler planimetry a valid technique for the evaluation of postpartum urinary bladder volume?Int Urogynecol J Pelvic Floor Dysfunct. 2008 Jul;19(7):1019-25. doi: 10.1007/s00192-007-0552-0. Epub 2008 Jan 30. Int Urogynecol J Pelvic Floor Dysfunct. 2008. PMID: 18231698
-
Determination of postvoid residual by translabial ultrasound.Int Urogynecol J. 2012 Dec;23(12):1749-52. doi: 10.1007/s00192-012-1769-0. Epub 2012 May 10. Int Urogynecol J. 2012. PMID: 22572918
References
MeSH terms
LinkOut - more resources
Medical