[Relationship between the presence of side-holes in bone marrow aspiration needle and the number of harvested bone marrow mononuclear cells]
- PMID: 9455143
[Relationship between the presence of side-holes in bone marrow aspiration needle and the number of harvested bone marrow mononuclear cells]
Abstract
The aim of this study was to evaluate the yield of nucleated cells in bone marrow harvested by means of Downs' Islam aspiration needles with or without side-holes. Twenty marrow donors for HLA identical sibling transplants were studied. Bone marrow nucleated cells were harvested 50 ml in the right iliac bone with a Downs' Islam aspiration needle with or without side-holes and 50 ml in the left with another kind of needle by means of 5 ml aspirations in each donor. There were no significant difference between the number of nucleated cells by means of Downs' Islam aspiration needles with and without side-holes by cross-over analysis. All nucleated cell counts were 33.06 +/- 12.93 x 10(3)/microliter (mean +/- standard deviation) by means of the needle with side-holes and 32.90 +/- 15.25 x 10(3)/microliter by means of the needle without side-holes. The Downs' Islam aspiration needle without side-holes seems to be better in bone marrow harvest from normal volunteers than that with side-holes, because the former may be stronger than the latter.
Similar articles
-
The effect of different harvest strategies on the nucleated cell yields of bone marrow collection.Biol Blood Marrow Transplant. 2011 Mar;17(3):351-5. doi: 10.1016/j.bbmt.2010.05.013. Epub 2010 May 27. Biol Blood Marrow Transplant. 2011. PMID: 20553925
-
Bone marrow harvest for marrow transplantation: effect of multiple small (2 ml) or large (20 ml) aspirates.Bone Marrow Transplant. 1992 Jun;9(6):467-70. Bone Marrow Transplant. 1992. PMID: 1628131
-
[Evaluation of the new bone marrow biopsy device, Jamshidi needle. Clinical importance of the bone marrow biopsy (author's transl)].Rinsho Ketsueki. 1976 Sep;17(9):956-62. Rinsho Ketsueki. 1976. PMID: 1034755 Japanese. No abstract available.
-
[Needles for bone marrow examination].Ugeskr Laeger. 1994 May 2;156(18):2723-4, 2727-8. Ugeskr Laeger. 1994. PMID: 8009711 Review. Danish.
-
Needle aspiration and biopsy in the diagnosis and monitoring of bone marrow diseases.Clin Lab Sci. 1996 Nov-Dec;9(6):349-53. Clin Lab Sci. 1996. PMID: 10165116 Review.
Cited by
-
Bone marrow aspirate concentrate quality is affected by age and harvest site.Knee Surg Sports Traumatol Arthrosc. 2023 Jun;31(6):2140-2151. doi: 10.1007/s00167-022-07153-6. Epub 2022 Sep 26. Knee Surg Sports Traumatol Arthrosc. 2023. PMID: 36156111 Free PMC article.
-
Factors affecting mesenchymal stromal cells yield from bone marrow aspiration.Chin J Cancer Res. 2011 Mar;23(1):43-8. doi: 10.1007/s11670-011-0043-1. Chin J Cancer Res. 2011. PMID: 23467386 Free PMC article.
-
Factors Influencing the Yield of Progenitor Cells in Bone Marrow Aspiration Concentrate-A Retrospective Analysis of 58 Patients.Biomedicines. 2023 Mar 1;11(3):738. doi: 10.3390/biomedicines11030738. Biomedicines. 2023. PMID: 36979718 Free PMC article.
-
Hematopoietic stem and progenitor cell harvesting: technical advances and clinical utility.J Blood Med. 2015 Feb 18;6:55-67. doi: 10.2147/JBM.S52783. eCollection 2015. J Blood Med. 2015. PMID: 25733943 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Research Materials