. 1997;6(6):402-5.
doi: 10.1007/BF01834068.

Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients

Affiliations

Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients

T Laine et al. Eur Spine J. 1997.

Abstract

A prospective study of the accuracy of titanium pedicle screw placement in 30 low back operations was performed. The postoperative plain radiographs and CT reformation images were evaluated by two independent radiologists. Thirty-two out of 152 screws (21%) perforated the pedicle cortex. One-tenth of the perforations was detected with conventional radiography. In ten patients (33%) all the screws were located within the pedicle. The clinical significance of this study lies in the finding that pedicle perforations are more frequent than is generally believed and that, in spite of the many malplacements, no screw that perforated by less than 4.0 mm caused neurological problems. Only one nerve root lesion was detected.

PubMed Disclaimer

References

    1. Castro WH, Halm H, Jerosch J, Malms J, Steinbeck J, Blasius S. Accuracy of pedicle screw placement in lumbar vertebrae. Spine. 1996;21:1320–1324. - PubMed
    1. Esses SI, Sachs BL, Dreyzin V. Complications associated with the technique of pedicle screw fixation — a selected survey of ABS members. Spine. 1993;18:2231–2239. - PubMed
    1. Farber GL, Place HM, Mazur RA, Jones C, Damiano TR. Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography. Spine. 1995;20:1494–1499. - PubMed
    1. George DC, Krag MH, Johnson CC, Hal ME, Haugh LD, Grobler LJ. Hole preparation techniques for transpedicle screws — effect on pullout strength from human cadaveric vertebrae. Spine. 1991;16:181–184. - PubMed
    1. Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine. 1990;15:11–14. - PubMed

MeSH terms

LinkOut - more resources