Inhaled nitric oxide and high frequency oscillatory ventilation in persistent pulmonary hypertension of the newborn
- PMID: 9462904
- DOI: 10.1007/pl00014288
Inhaled nitric oxide and high frequency oscillatory ventilation in persistent pulmonary hypertension of the newborn
Abstract
Inhaled nitric oxide (iNO) improves oxygenation in near-term and term newborns with persistent pulmonary hypertension of the newborn (PPHN), and decreases the need for treatment with extracorporeal membrane oxygenation. However, some patients with PPHN either do not respond or have only transient improvements in oxygenation during iNO therapy. Extrapulmonary shunting associated with high pulmonary vascular resistance in PPHN can cause critical hypoxaemia; however, the syndrome of PPHN is often associated with severe parenchymal lung disease (e.g., meconium aspiration pneumonitis, bacterial pneumonia, and surfactant deficiency) which causes intrapulmonary shunting. It is increasingly recognized that the effective use of iNO requires adequate lung inflation to optimize delivery of the drug within the lung. High frequency oscillatory ventilation (HFOV) causes safe and effective lung recruitment when an appropriate strategy is applied and has recently been shown to improve the response to iNO when parenchymal lung disease occurs in association with PPHN.
Conclusion: Recent studies have shown that HFOV augments the response to iNO in PPHN associated with meconium aspiration syndrome or diffuse parenchymal lung disease (pneumonia, respiratory distress syndrome). Suboptimal lung inflation compromises the efficacy of iNO in PPHN, and may in part explain the reported differences in iNO response rates.
Similar articles
-
Randomized, multicenter trial of inhaled nitric oxide and high-frequency oscillatory ventilation in severe, persistent pulmonary hypertension of the newborn.J Pediatr. 1997 Jul;131(1 Pt 1):55-62. doi: 10.1016/s0022-3476(97)70124-0. J Pediatr. 1997. PMID: 9255192 Clinical Trial.
-
Disease-related response to inhaled nitric oxide in newborns with severe hypoxaemic respiratory failure. French Paediatric Study Group of Inhaled NO.Eur J Pediatr. 1998 Sep;157(9):747-52. doi: 10.1007/s004310050928. Eur J Pediatr. 1998. PMID: 9776535
-
Methemoglobin to cumulative nitric oxide ratio and response to inhaled nitric oxide in PPHN.J Perinatol. 2009 Oct;29(10):698-701. doi: 10.1038/jp.2009.69. Epub 2009 Jun 25. J Perinatol. 2009. PMID: 19554014
-
Current and future therapeutic options for persistent pulmonary hypertension in the newborn.Expert Rev Cardiovasc Ther. 2010 Jun;8(6):845-62. doi: 10.1586/erc.09.186. Expert Rev Cardiovasc Ther. 2010. PMID: 20528642 Review.
-
Recent developments in the pathophysiology and treatment of persistent pulmonary hypertension of the newborn.J Pediatr. 1995 Jun;126(6):853-64. doi: 10.1016/s0022-3476(95)70197-4. J Pediatr. 1995. PMID: 7776084 Review.
Cited by
-
Innovative neonatal ventilation and meconium aspiration syndrome.Indian J Pediatr. 2003 May;70(5):421-7. doi: 10.1007/BF02723617. Indian J Pediatr. 2003. PMID: 12841404
-
Evidence-Based Guidelines for Acute Stabilization and Management of Neonates with Persistent Pulmonary Hypertension of the Newborn.Am J Perinatol. 2023 Oct;40(14):1495-1508. doi: 10.1055/a-1711-0778. Epub 2021 Dec 1. Am J Perinatol. 2023. PMID: 34852367 Free PMC article.
-
Cardiovascular effects of mechanical ventilation.Arch Dis Child. 1999 May;80(5):475-80. doi: 10.1136/adc.80.5.475. Arch Dis Child. 1999. PMID: 10208959 Free PMC article. Review. No abstract available.
-
Advances in management of meconium aspiration syndrome.Indian J Pediatr. 2000 Nov;67(11):837-41. doi: 10.1007/BF02726230. Indian J Pediatr. 2000. PMID: 11216385 Review.
-
Nitric oxide and pulmonary hypertension.Korean J Anesthesiol. 2010 Jan;58(1):4-14. doi: 10.4097/kjae.2010.58.1.4. Epub 2010 Jan 31. Korean J Anesthesiol. 2010. PMID: 20498805 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources