Radiological evaluation and management of malfunctioning central venous catheters
- PMID: 9464429
- DOI: 10.1016/s0009-9260(98)80027-5
Radiological evaluation and management of malfunctioning central venous catheters
Abstract
Central venous catheters provide an important means of long-term vascular access in a variety of clinical situations. Catheter placement and evaluation is now forming an increasing part of the workload of interventional radiologists. This review presents an overview of malfunctioning central venous catheters. We outline the causes of catheter related problems and discuss the treatment options. We include examples of catheter malfunction resulting from malposition, displacement, kinking and occlusion.
Comment in
-
Malfunctioning central venous catheters.Clin Radiol. 1998 Sep;53(9):708-9. doi: 10.1016/s0009-9260(98)80305-x. Clin Radiol. 1998. PMID: 9766731 No abstract available.
Similar articles
-
Malfunctioning central venous catheters in children: a diagnostic approach.Pediatr Radiol. 2008 Apr;38(4):363-78, quiz 486-7. doi: 10.1007/s00247-007-0610-2. Epub 2007 Oct 12. Pediatr Radiol. 2008. PMID: 17932667 Free PMC article. Review.
-
Malfunctioning central venous catheters.Clin Radiol. 1998 Sep;53(9):708-9. doi: 10.1016/s0009-9260(98)80305-x. Clin Radiol. 1998. PMID: 9766731 No abstract available.
-
Central venous catheter tip malposition.J Med Imaging Radiat Oncol. 2010 Feb;54(1):35-42. doi: 10.1111/j.1754-9485.2010.02143.x. J Med Imaging Radiat Oncol. 2010. PMID: 20377713 Review.
-
Intravascular access devices from an interventional radiology perspective: indications, implantation techniques, and optimizing patency.Transfusion. 2018 Feb;58 Suppl 1:549-557. doi: 10.1111/trf.14501. Transfusion. 2018. PMID: 29443411 Review.
-
[Dysfunctioning of central venous catheters: role of the radiologist].Nephrologie. 2001;22(8):425-7. Nephrologie. 2001. PMID: 11811002 French.
Cited by
-
A quantitative analysis of the relation between the clavicular tilt angle and subclavian central venous catheter misplacement.Clin Exp Emerg Med. 2014 Dec 31;1(2):114-119. doi: 10.15441/ceem.14.003. eCollection 2014 Dec. Clin Exp Emerg Med. 2014. PMID: 27752562 Free PMC article.
-
Correction of malposition of central venous catheter with 9-Fr introducer sheath assisted by mobile type diagnostic X-ray apparatus: a case report.Korean J Anesthesiol. 2015 Aug;68(4):402-6. doi: 10.4097/kjae.2015.68.4.402. Epub 2015 Jul 28. Korean J Anesthesiol. 2015. PMID: 26257855 Free PMC article.
-
Hemodialysis catheter insertion: is increased PO2 a sign of arterial cannulation? A case report.BMC Nephrol. 2014 Jul 29;15:127. doi: 10.1186/1471-2369-15-127. BMC Nephrol. 2014. PMID: 25073708 Free PMC article.
-
Saline Flush versus Chest x ray in Confirmation of Central Venous Catheter Placement; a Diagnostic Accuracy Study.Emerg (Tehran). 2017;5(1):e75. Epub 2017 Aug 8. Emerg (Tehran). 2017. PMID: 29201957 Free PMC article.
-
Displacement of optimally placed subclavian central venous catheter by dialysis catheter - retrospection after radiography.J Anaesthesiol Clin Pharmacol. 2014 Jul;30(3):435-6. doi: 10.4103/0970-9185.137293. J Anaesthesiol Clin Pharmacol. 2014. PMID: 25190965 Free PMC article. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources