Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1997 Aug;89(5-6):299-306.

Length of the selectivity filter of aquaporin-1

Affiliations
  • PMID: 9468600

Length of the selectivity filter of aquaporin-1

G Whittembury et al. Biol Cell. 1997 Aug.

Abstract

We have characterized the selectivity filter of the water channel aquaporin-1 (AQP1) of proximal straight tubules (PST), as an equivalent cylindrical structure with a diameter of approximately 4.5 A, where water molecules single file. We report here efforts to evaluate its length. PST were dissected from rabbit kidneys, held with pipettes in a chamber bathed in a buffered mannitol isosmotic solution (MBS, 295 mOsm/kg). Changes in tubule cell volume with time (dV/Adt), were monitored, on line, with an inverted microscope, a TV camera and an image processor. Osmotic permeability coefficients, Pos, and reflection coefficients (sigma s) were measured with several solutes: mannitol (M), raffinose (R), sucrose (S), glycerol (G), acetamide (A) and urea (U). For this purpose PST were suddenly exposed (in approximately 80 ms and for 20 s) to a hyperosmolality step (delta Cs) achieved by adding to MBS a delta Cs of 35 mOsm/kg of either R, S, M, G, A or U. Cells shrunk within 500 ms of t = 0 to their osmometric volume and remained shrunk for the 20 s of the delta Cs. Pos was measured from the shrinking curves; Pos = 3000 +/- 25 microns/s with either R, S, M, G, A or U. This procedure also allowed to calculate sigma s; sigma s = 1.00 for R, S, M, G, A and U, indicating that these solutes do not penetrate the water channel. In contrast, the shrinking curves produced by a delta Cs = 35 mOsm/kg formamide (F) were 1/5th to 1/6th slower and smaller (subosmometric) than those produced by a delta Cs = 35 mOsm/kg of R, S, M, G, A or U. Furthermore, with F, cells did not remain shrunk. They recovered their original volume within 3 s. Pos (measured with F) is denoted as Pos*; Pos* = 480 +/- 30 microns/s. sigma s, formamide (denoted sigma sp) = 0.16 +/- 0.01. Use of sigma sp and Pos* values in Hill's equations for the bimodal theory of osmosis leads to n = 2-3, n being the number of water molecules single filing within the channel selectivity filter, whose length must lie within 6 to 9 A, a value lower than previous values calculated from the Pos/Pd* ratio.

PubMed Disclaimer

Similar articles

Publication types

LinkOut - more resources