Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1997 Dec 3;35(3):161-74.
doi: 10.1016/s0165-022x(97)00037-7.

A high speed optical multichannel analyzer

Affiliations

A high speed optical multichannel analyzer

J W Cole et al. J Biochem Biophys Methods. .

Abstract

An optical multichannel analyzer capable of recording spectra at sampling rates up to 100 kHz is described. The instrument, designed to gather data on the kinetic reaction mechanisms of biological preparations such as cytochrome oxidase and bacteriorhodopsin, features a massively parallel approach in which each photosensing element of the detector array has a dedicated amplifier, integrator, analog to digital converter, and sample buffer. The design has 92 such elements divided in two separate arrays, each of which sits at the focal plane of a 1/4 m Ebert spectrometer. The spectrometers may be tuned to cover independent, 130 nm wide, regions of the spectrum from 350 nm to 900 nm with a dispersion of 2.8 nm per element. Each detection channel has 12-bit resolution with an electronic dark count of 1 count and may be sampled 1024 times during a single experiment with dynamically variable sampling intervals from 10 microseconds to several seconds. Time averaging of up to thousands of consecutive laser-initiated kinetic cycles allows analyses of spectral changes < 0.001 optical density units. A personal computer with custom software provides a number of features: entry of experiment parameters; transfer of data from temporary buffers to permanent files; real time display; multiple spectrum averaging; and control and synchronization of associated system hardware. Optical fibers or lenses provide coupling from a parabolic reflector Xenon arc monitoring light source, through the sample chamber, to the entry slit of the monochromator. The instrument has been used for extensive studies on the rapid kinetics and definition of reaction sequences of the energy-transducing enzymes cytochrome oxidase and bacteriorhodopsin. Some results from these studies are discussed.

PubMed Disclaimer

Substances

LinkOut - more resources