Pattern electroretinograms were recorded to phase-reversing checkerboard stimuli with DTL electrodes under conditions close to those of the ISCEV pattern electroretinogram guidelines. Both transient (2 reversals/s) and steady-state (16 reversals/s) stimulation was used. The check sizes were 0.4 degree, 0.8 degree and 16 degrees; the mean luminance 45 cd/m2, the contrast 98%, and the field size 32 degrees x 27 degrees. In 42 eyes of 21 subjects, measurements were repeated at the same time of day after 1 week. For each eye, the intersession coefficient of variation was calculated as a measure of reproducibility. We found a coefficient of variation (+/- standard deviation) of 7% +/- 5% for the amplitude of the steady-state pattern electroretinogram, 9.5% +/- 7% for the transient pattern electroretinogram and 1.5% +/- 2% for the latency of the transient pattern electroretinogram. To assess the diurnal variability, during a 15-h period, three pattern electroretinograms were recorded in 10 subjects. No relationship was found between the P50 latency and the time of day. However, the mean amplitude showed a maximum in the morning (9:30 am) and a minimum in the afternoon (2:30 pm). This small effect (about 7%, p < 0.001) was more pronounced for N95 and steady-state amplitudes than for P50 amplitudes (p < 0.01). Diurnal contributions to the pattern electroretinogram ranged between 3% and 10%. We conclude that pattern electroretinogram amplitude reproduces within +/- 10% with a probability of 70%. The effect size of the diurnal variation is similar and might be relevant for longitudinal studies.
Similar articles
-
[Reproducibility of the pattern electroretinogram].Ophthalmologe. 1997 Mar;94(3):217-21. doi: 10.1007/s003470050105. Ophthalmologe. 1997. PMID: 9181839 German.
-
Check size tuning of the pattern electroretingoram: a reappraisal.Doc Ophthalmol. 1996-1997;92(3):193-202. doi: 10.1007/BF02583290. Doc Ophthalmol. 1996. PMID: 9181346
-
Steady-state pattern electroretinogram and short-duration transient visual evoked potentials in glaucomatous and healthy eyes.Clin Exp Ophthalmol. 2018 Jan;46(1):54-61. doi: 10.1111/ceo.13006. Epub 2017 Jul 20. Clin Exp Ophthalmol. 2018. PMID: 28600806
-
Update on the pattern electroretinogram in glaucoma.Optom Vis Sci. 2008 Jun;85(6):386-95. doi: 10.1097/OPX.0b013e318177ebf3. Optom Vis Sci. 2008. PMID: 18521020 Review.
-
Pattern-reversal electroretinograms for the diagnosis and management of disorders of the anterior visual pathway.Arq Bras Oftalmol. 2011 May-Jun;74(3):222-6. doi: 10.1590/s0004-27492011000300017. Arq Bras Oftalmol. 2011. PMID: 21915454 Review.
Cited by
-
Monitoring for glaucoma progression with SAP, electroretinography (PERG and PhNR) and OCT.Doc Ophthalmol. 2022 Feb;144(1):17-30. doi: 10.1007/s10633-021-09854-8. Epub 2021 Oct 15. Doc Ophthalmol. 2022. PMID: 34652598 Free PMC article.
-
Effect of eccentric fixation on the steady-state pattern electroretinogram.Doc Ophthalmol. 2024 Apr;148(2):87-95. doi: 10.1007/s10633-024-09967-w. Epub 2024 Feb 28. Doc Ophthalmol. 2024. PMID: 38416305 Free PMC article.
-
Intra-sessional and inter-sessional variability of multifocal electroretinogram.Doc Ophthalmol. 2008 Nov;117(3):175-83. doi: 10.1007/s10633-008-9119-8. Epub 2008 Mar 6. Doc Ophthalmol. 2008. PMID: 18322719
-
Retinal ganglion cell activity from the multifocal electroretinogram in pig: optic nerve section, anaesthesia and intravitreal tetrodotoxin.J Physiol. 2006 Jan 15;570(Pt 2):325-38. doi: 10.1113/jphysiol.2005.098046. Epub 2005 Nov 10. J Physiol. 2006. PMID: 16284074 Free PMC article.
-
Little correlation of the pattern electroretinogram (PERG) and visual field measures in early glaucoma.Doc Ophthalmol. 1997-1998;94(3):253-63. doi: 10.1007/BF02582983. Doc Ophthalmol. 1997. PMID: 9682994
References
MeSH terms
LinkOut - more resources
Research Materials