Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1998 Feb;12(2):115-8.
doi: 10.1007/s004649900609.

The effects of pneumoperitoneum on gastric blood flow and traditional hemodynamic measurements

Affiliations
Comparative Study

The effects of pneumoperitoneum on gastric blood flow and traditional hemodynamic measurements

T J Knolmayer et al. Surg Endosc. 1998 Feb.

Abstract

Background: The purpose of this study was to investigate the effects of increasing intraabdominal pressure (IP) on gastric blood flow, as measured by gastric tonometry and traditional hemodynamic measurements.

Methods: Nine swine were anesthetized, intubated, and ventilated. Arterial and pulmonary artery catheters were placed by cutdown, a trocar was placed in the abdomen, and a gastric tonometer was placed in the stomach. Serial measurements of arterial and mixed venous blood gases, cardiac output, wedge pressure, lactic acid, and gastric intramucosal pH (pHi) were collected at intraperitoneal pressures of 0, 8, 10, 12, 14, 16, and 18 mm Hg after 30 min equilibration. Statistical analysis included Pearson correlation and Student's t test.

Results: Increasing levels of IP were correlated with decreased arterial pH (p < 0.00003), increased mixed venous CO2 (p < 0.003), decreased intramucosal pH (p < 0.014), and increased arterial CO2 (p < 0.015). Gastric pHi differed significantly from baseline at IP levels of 16 mm Hg (p < 0.004) and 18 mm Hg (p < 0.01). No significant effects were observed on cardiac output or arterial lactate. No significant effects were observed in a control group that had been insufflated to 8 mm Hg and held constant over 3 h.

Conclusions: In this model, gastric blood flow is adversely affected by increasing i.p. with pronounced effects in excess of 15 mm Hg. These results suggest that gastric tonometry may be used to monitor the adverse effects of pneumoperitoneum. Gastric pHi may be an earlier indicator of altered hemodynamic function during laparoscopy than traditional measures.

PubMed Disclaimer

Comment in

Publication types

LinkOut - more resources