Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1998 Mar 15;26(6):1396-400.
doi: 10.1093/nar/26.6.1396.

Denaturing high performance liquid chromatography (DHPLC) used in the detection of germline and somatic mutations

Affiliations
Comparative Study

Denaturing high performance liquid chromatography (DHPLC) used in the detection of germline and somatic mutations

W Liu et al. Nucleic Acids Res. .

Abstract

Denaturing high performance liquid chromatography (DHPLC) has been described recently as a method for screening DNA samples for single nucleotide polymorphisms and inherited mutations. Thirty-eight DNAs, 22 of which were heterozygous for previously characterized rearranged transforming gene (RET) or cystic fibrosis transmembrane conductance regulator gene (CFTR) mutations or polymorphisms, were examined using DHPLC analysis to assess the accuracy of this scanning method. Ninety-one per cent (20/22) of the PCR amplicons from specimens with heterozygous RET or CFTR sequence showed elution profiles distinct from corresponding homozygous normal patterns; whether the profiles for two amplicons containing heterozygous RET sequence were distinct from homozygous cases was equivocal. To investigate the usefulness of this method for detecting mutations in tumor DNAs, each of the phosphatase and tensin homologue deleted on chromosome ten gene (PTEN) exons were examined for mutations in 63 malignant gliomas. Seventeen PTEN PCR products from this series of brain tumors showed elution profiles indicating sample heterozygosity and in each instance conventional sequencing confirmed the presence of a mutation. PTEN amplicons containing exons 1, 3 and 5 were sequenced for each of the 63 tumor DNAs to determine whether any mutations may have escaped DHPLC detection, and this analysis identified one such alteration in addition to the eight mutations that DHPLC had revealed. In total, DHPLC identified 37 of 40 (92.5%) PCR products containing defined sequence variation and no alterations were indicated among 196 amplicons containing homozygous normal sequence.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Cancer Res. 1988 Oct 1;48(19):5546-51 - PubMed
    1. Genome Res. 1997 Oct;7(10):996-1005 - PubMed
    1. Nucleic Acids Res. 1993 Mar 11;21(5):1061-6 - PubMed
    1. Anal Biochem. 1993 Aug 1;212(2):351-8 - PubMed
    1. Nat Genet. 1993 Oct;5(2):111-7 - PubMed

Publication types

MeSH terms

Substances