Flow-cytometric analysis of leukocyte activation induced by polyethylene-terephthalate with and without pyrolytic carbon coating
- PMID: 9492214
- DOI: 10.1002/(sici)1097-4636(19980315)39:4<549::aid-jbm7>3.0.co;2-j
Flow-cytometric analysis of leukocyte activation induced by polyethylene-terephthalate with and without pyrolytic carbon coating
Abstract
Leukocyte activation is one test for the evaluation of blood-materials interaction. The expression of adhesion molecules analyzed by flow cytometry provides a simple method to evaluate leukocyte activation by biomaterials: any change in these molecules can be predictive of the inflammatory activity of the materials. In this study the contact between leukocytes and uncoated polyethylene terephthalate or pyrolytic carbon-coated polyethylene terephthalate (PET and PET-PC, respectively) was inspected by analyzing whether the expression of some adhesion molecules involved in leukocyte activation, namely LFA-1 (CD11a/ CD18), Mac-1/CR3 (CD11b/CD18), and LECAM-1 (CD62L) can be modified. By flow cytometry expression of the adhesion molecules can be studied separately on lymphocytes and myeloid cells. The materials tested reduced the total numbers of both leukocytes and neutrophils, although not significantly. Neither PET nor PET-PC changed the expression of the adhesion molecules in lymphocytes: this suggests that no specific immune response is stimulated. On the contrary, statistically significant changes were observed for monocytes and granulocytes: the percentage of cells expressing Mac-1 and the density of such antigens on cell membranes increased while the percentage of LECAM-1 positive cells decreased. Similar changes were observed when the cells underwent the inflammatory stimulus provided by an in vitro challenge with bacterial endotoxin. Our results demonstrated that polyethylene terephthalate activates leukocytes by modifying the expression in neutrophils of the molecules involved in the early phase of the inflammatory response. Even after coating PET with pyrolytic carbon, the ability of this material to activate circulating leukocytes was maintained.
Similar articles
-
Adhesive protein expression on endothelial cells after contact in vitro with polyethylene terephthalate coated with pyrolytic carbon.Biomaterials. 1995 Nov;16(16):1223-7. doi: 10.1016/0142-9612(95)98128-2. Biomaterials. 1995. PMID: 8589191
-
Platelet and coagulation factor variations induced in vitro by polyethylene terephthalate (Dacron) coated with pyrolytic carbon.Biomaterials. 1995 Sep;16(13):973-6. doi: 10.1016/0142-9612(95)94903-x. Biomaterials. 1995. PMID: 8580259
-
Phenotyping analysis of peripheral blood leukocytes in patients with multiple sclerosis.Eur J Neurol. 1999 May;6(3):347-52. doi: 10.1046/j.1468-1331.1999.630347.x. Eur J Neurol. 1999. PMID: 10210917
-
Exploring the potential of polyethylene terephthalate in the design of antibacterial surfaces.Med Microbiol Immunol. 2020 Jun;209(3):363-372. doi: 10.1007/s00430-020-00660-8. Epub 2020 Feb 9. Med Microbiol Immunol. 2020. PMID: 32037497 Free PMC article. Review.
-
Applications of flow cytometry in the analysis of blood leukocytes.Transfus Sci. 1995 Dec;16(4):333-41. doi: 10.1016/0955-3886(95)00044-5. Transfus Sci. 1995. PMID: 10159504 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials