Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1998 Mar;206(3):755-60.
doi: 10.1148/radiology.206.3.9494497.

Staging of primary colorectal carcinomas with fluorine-18 fluorodeoxyglucose whole-body PET: correlation with histopathologic and CT findings

Affiliations

Staging of primary colorectal carcinomas with fluorine-18 fluorodeoxyglucose whole-body PET: correlation with histopathologic and CT findings

H Abdel-Nabi et al. Radiology. 1998 Mar.

Abstract

Purpose: To evaluate the diagnostic usefulness of positron emission tomography (PET) with fluorine-18 fluorodeoxyglucose (FDG) in patients with primary colorectal carcinomas.

Materials and methods: Forty-eight patients with biopsy-proved (n = 44) or high clinical suspicion for (n = 4) colorectal cancer underwent whole-body PET after intravenous administration of 10 mCi (370 MBq) of FDG. FDG PET results were correlated with computed tomographic (CT), surgical, and histopathologic findings.

Results: PET depicted all known intraluminal carcinomas in 37 patients (including two in situ carcinomas) (sensitivity, 100%), but findings were false-positive in four of seven patients without cancer (three with inflammatory bowel conditions, one who had undergone polypectomy). Specificity was 43% (three of seven patients); positive predictive value, 90% (37 of 41 patients); and negative predictive value, 100% (three of three patients). No FDG accumulation was noted in 35 hyperplastic polyps. FDG PET depicted lymph node metastases in four of 14 patients (sensitivity, 29%). Results were similar to those obtained with CT (true-positive, two of seven patients [sensitivity, 29%]; true-negative, 22 of 26 patients [specificity, 85%]). FDG PET depicted liver metastases in seven of eight patients and was superior to CT, which depicted liver metastases in three patients (sensitivity of 88% and 38%, respectively). FDG PET and CT, respectively, correctly depicted the absence of liver metastases in 35 and 32 patients (specificity, 100% and 97%; negative predictive value, 97% and 86%).

Conclusion: FDG PET has a high sensitivity and specificity for detection of colorectal carcinomas (primary and liver metastases) and appears to be superior to CT in the staging of primary colorectal carcinoma.