Lactosorb panel and screws for repair of large orbital floor defects
Abstract
In a series of five patients with extensive fractures of the orbital floor, we used a biodegradable sheet for bridging of the bony defects. To achieve optimal support of the orbital contents in their anatomically correct position, we fixed the sheet with at least two resorbable screws to the infraorbital rim. This new technique appears to be superior to conventional methods because it offers reproducible results without the need for secondary interventions.
Comment in
-
Lactosorb panel and screws for repair of large orbital floor defects.J Craniomaxillofac Surg. 1998 Jun;26(3):191-2. doi: 10.1016/s1010-5182(98)80012-7. J Craniomaxillofac Surg. 1998. PMID: 9702640 No abstract available.
Similar articles
-
Lactosorb panel and screws for repair of large orbital floor defects.J Craniomaxillofac Surg. 1998 Jun;26(3):191-2. doi: 10.1016/s1010-5182(98)80012-7. J Craniomaxillofac Surg. 1998. PMID: 9702640 No abstract available.
-
Transantral endoscopic orbital floor repair using resorbable plate.J Craniofac Surg. 2002 May;13(3):483-8; discussion 488-9. doi: 10.1097/00001665-200205000-00022. J Craniofac Surg. 2002. PMID: 12040223
-
Use of copolymer polylactic and polyglycolic acid resorbable plates in repair of orbital floor fractures.Facial Plast Surg. 2014 Oct;30(5):581-6. doi: 10.1055/s-0034-1393697. Epub 2014 Nov 14. Facial Plast Surg. 2014. PMID: 25397715
-
Biodegradable fracture-fixation devices in maxillofacial surgery.Int J Oral Maxillofac Surg. 1993 Feb;22(1):50-7. doi: 10.1016/s0901-5027(05)80358-3. Int J Oral Maxillofac Surg. 1993. PMID: 8384646 Review. No abstract available.
-
Pediatric zygomatico-orbital complex fractures: the use of resorbable plating systems. A case report.J Craniomaxillofac Trauma. 1998 Winter;4(4):32-6. J Craniomaxillofac Trauma. 1998. PMID: 11951279 Review.
Cited by
-
Effective correction of frontal cranial deformities using biodegradable fixation on the inner surface of the cranial bones during infancy.Childs Nerv Syst. 2007 Dec;23(12):1439-45. doi: 10.1007/s00381-007-0470-y. Epub 2007 Sep 28. Childs Nerv Syst. 2007. PMID: 17901962
-
Efficacy of Two-Point Versus Three-Point Fixation for Zygomaticomaxillary Fractures: A Systematic Review and Meta-analysis.J Maxillofac Oral Surg. 2024 Oct;23(5):1166-1174. doi: 10.1007/s12663-024-02139-y. Epub 2024 Mar 14. J Maxillofac Oral Surg. 2024. PMID: 39376747 Review.
-
The Use of Functional Biomaterials in Aesthetic and Functional Restoration in Orbital Surgery.J Funct Biomater. 2024 Jan 29;15(2):33. doi: 10.3390/jfb15020033. J Funct Biomater. 2024. PMID: 38391886 Free PMC article. Review.
-
Surface delivery of tunable doses of BMP-2 from an adaptable polymeric scaffold induces volumetric bone regeneration.Biomaterials. 2016 Oct;104:168-81. doi: 10.1016/j.biomaterials.2016.06.001. Epub 2016 Jun 29. Biomaterials. 2016. PMID: 27454063 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources