Pneumatonographic studies on normal and glaucomatus eyes
- PMID: 952242
Pneumatonographic studies on normal and glaucomatus eyes
Abstract
A new methodological approach, embodied in the pneumatonograph, has been used to study the intraocular pressure, intraocular pulse and aqueous humor dynamics of normal and glaucomatous eyes. Comparative measurements of intraocular pressure in seated subjects by the Goldmann instrument and the pneumatonograph indicate close agreement over a wide range of pressures. On changing from the sitting to the supine position, it has been found by pneumatonometry that there is a significant increase of intraocular pressure in all eyes. In glaucomatous eyes, this postural response ranged up to as high as 12 mm Hg. Comparison of Schiotz and pneumatonometric pressure measurements on supine patients showed that the Schoitz values are significantly lower. This discrepancy of the values is in keeping with recent studies indicative that the Schiotz calibration is in error by 3-6 mm Hg. The coefficient of outflow facility was measured by a procedure of applanation tonography employing pressure-volume relations for the living human eye. The range of values found for normal eyes was significantly different from those of glaucoma eyes. It is concluded that pneumatonography is a useful method for improving the effectiveness of glaucoma diagnosis and clinical management.
Similar articles
-
Aqueous humor outflow facility by tonography does not change with body position.Invest Ophthalmol Vis Sci. 2010 Mar;51(3):1453-7. doi: 10.1167/iovs.09-4058. Epub 2009 Dec 3. Invest Ophthalmol Vis Sci. 2010. PMID: 19959645
-
[Intraocular pressure difference in Goldmann applanation tonometry versus a transpalpebral tonometer TGDc-01"PRA" in glaucoma patients].Klin Monbl Augenheilkd. 2005 Feb;222(2):123-31. doi: 10.1055/s-2005-857881. Klin Monbl Augenheilkd. 2005. PMID: 15719316 Clinical Trial. German.
-
A comparison between an acetazolamide test and weight tonography in pathological and apathological circulation of the aqueous humor.Invest Ophthalmol. 1976 Oct;15(10):844-8. Invest Ophthalmol. 1976. PMID: 977254
-
[Biological and physical aspects of intraocular pressure].Klin Monbl Augenheilkd. 2011 Feb;228(2):98-103. doi: 10.1055/s-0029-1246078. Epub 2011 Feb 15. Klin Monbl Augenheilkd. 2011. PMID: 21328168 Review. German.
-
Measurement of episcleral venous pressure.Exp Eye Res. 2011 Sep;93(3):291-8. doi: 10.1016/j.exer.2011.05.003. Epub 2011 May 20. Exp Eye Res. 2011. PMID: 21621536 Review.
Cited by
-
Comparison of outflow facility before and after the microhook ab interno trabeculotomy.Eye (Lond). 2022 Apr;36(4):760-765. doi: 10.1038/s41433-021-01524-y. Epub 2021 Apr 12. Eye (Lond). 2022. PMID: 33846577 Free PMC article.
-
Acute Effects of Intraocular Pressure-Induced Changes in Schlemm's Canal Morphology on Outflow Facility in Healthy Human Eyes.Invest Ophthalmol Vis Sci. 2020 Jul 1;61(8):36. doi: 10.1167/iovs.61.8.36. Invest Ophthalmol Vis Sci. 2020. PMID: 32716504 Free PMC article.
-
Effects of Vitrectomy and Lensectomy on Older Rhesus Macaques: Oxygen Distribution, Antioxidant Status, and Aqueous Humor Dynamics.Invest Ophthalmol Vis Sci. 2017 Aug 1;58(10):4003-4014. doi: 10.1167/iovs.17-21890. Invest Ophthalmol Vis Sci. 2017. PMID: 28800647 Free PMC article.
-
Comparison of Corneal Wave Speed and Ocular Rigidity in Normal and Glaucomatous Eyes.J Glaucoma. 2021 Oct 1;30(10):932-940. doi: 10.1097/IJG.0000000000001901. J Glaucoma. 2021. PMID: 34127628 Free PMC article.
-
Comparison of Aqueous Outflow Facility Measurement by Pneumatonography and Digital Schiøtz Tonography.Invest Ophthalmol Vis Sci. 2017 Jan 1;58(1):204-210. doi: 10.1167/iovs.16-20754. Invest Ophthalmol Vis Sci. 2017. PMID: 28114581 Free PMC article. Clinical Trial.