Isotachophoresis at pH extremes: theory and experimental validation
- PMID: 9548279
- DOI: 10.1002/elps.1150190210
Isotachophoresis at pH extremes: theory and experimental validation
Abstract
The evolution of an isotachophoresis (ITP) system in acidic or basic pH ranges can be quite different from that predicted by the existing theory. It was found theoretically and proved experimentally that the contribution of hydrogen or hydroxyl ion to conductivity of solution and/or its net charge changes the behavior of the ITP system, creating in the terminating electrolyte an additional zone close to the initial interfaces between electrolytes (leader and terminator). One boundary of the zone, being either sharp or dispersed, moves toward the leader; the other is always sharp and stationary and coincides with initial electrolytes' discontinuity. The latter can be registered in the presence of electroosmotic flow which delivers it to the detection point. In order to describe the dynamics of the ITP system at pH extremes an algorithm of analytical solution was developed, based on the revised Kohlrausch theory. Its predictions coincide well with computer simulations and experimental data. The results presented can help in a correct analysis of ITP data and explain some confusing phenomena which were considered to be artifacts.
Similar articles
-
Determination of trace cationic impurities in butylmethylimidazolium-based ionic liquids: from transient to comprehensive single-capillary counterflow isotachophoresis-zone electrophoresis.Electrophoresis. 2006 Dec;27(23):4859-71. doi: 10.1002/elps.200600316. Electrophoresis. 2006. PMID: 17136724
-
Unlimited-volume stacking of ions in capillary electrophoresis. Part 1: stationary isotachophoretic stacking of anions.Electrophoresis. 2008 Mar;29(5):1082-91. doi: 10.1002/elps.200700728. Electrophoresis. 2008. PMID: 18271067
-
Synergism of capillary isotachophoresis and capillary zone electrophoresis.J Chromatogr B Biomed Sci Appl. 1997 Feb 7;689(1):13-34. J Chromatogr B Biomed Sci Appl. 1997. PMID: 9061479 Review.
-
Ionic strength effects on electrophoretic focusing and separations.Electrophoresis. 2010 Mar;31(5):910-9. doi: 10.1002/elps.200900560. Electrophoresis. 2010. PMID: 20191554
-
Dynamic computer simulations of electrophoresis: a versatile research and teaching tool.Electrophoresis. 2010 Mar;31(5):726-54. doi: 10.1002/elps.200900613. Electrophoresis. 2010. PMID: 20191541 Review.
Cited by
-
Isotachophoresis: Theory and Microfluidic Applications.Chem Rev. 2022 Aug 10;122(15):12904-12976. doi: 10.1021/acs.chemrev.1c00640. Epub 2022 Jun 22. Chem Rev. 2022. PMID: 35732018 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources