Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1998 Apr;27(4):276-84.
doi: 10.2519/jospt.1998.27.4.276.

Clinical tests for ankle syndesmosis injury: reliability and prediction of return to function

Affiliations

Clinical tests for ankle syndesmosis injury: reliability and prediction of return to function

A Alonso et al. J Orthop Sports Phys Ther. 1998 Apr.

Abstract

Despite the severity of ankle syndesmosis injuries, it has been argued that they are relatively poorly detected. This study investigated the interrater reliability of four orthopaedic tests for ankle syndesmosis injury and assessed their ability to predict the extended recovery times that have been reported as a consequence of this injury. Nine physiotherapists, working in random pairings, examined 53 subjects, all receiving treatment for ankle injury at two private clinics. Each subject was tested by two physiotherapists who independently performed the palpation test, external rotation test, squeeze test, and dorsiflexion-compression test. Kappa coefficient testing indicated that the external rotation test had the best interrater reliability (kappa = 0.75). The squeeze test was found to have moderate reliability (kappa = 0.50), and the palpation and dorsiflexion-compression tests both had only fair reliability (kappa = 0.36). The degree of pair-wise association between the results of the four tests was low (phi < or = 0.30 for all test combinations), suggesting that if all four tests were performed on the same subject, it was not likely that they would achieve similar results. Follow-up interviews were conducted to determine the time taken for subjects to walk 10 m without pain and, for sports injuries, the time taken to return to training and then to competition. For each test, Mann-Whitney U values showed no significant difference between the recovery times of subjects with positive or negative test results, although subjects with recovery times markedly longer than normal were detected by three of the four tests. When an either/or combination of the external rotation and dorsiflexion-compression tests was considered, subjects with a positive test result took significantly longer to return to playing sports.

PubMed Disclaimer

LinkOut - more resources