Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1998 Mar 20;706(2):231-44.
doi: 10.1016/s0378-4347(97)00560-4.

Quantitative analysis of polychlorinated biphenyls, organochlorine insecticides, polycyclic aromatic hydrocarbons, polychlorinated hydrocarbons and polynitrohydrocarbons in spiked samples of soil, water and plasma by selected-ion monitoring gas chromatography-mass spectrometry

Affiliations
Comparative Study

Quantitative analysis of polychlorinated biphenyls, organochlorine insecticides, polycyclic aromatic hydrocarbons, polychlorinated hydrocarbons and polynitrohydrocarbons in spiked samples of soil, water and plasma by selected-ion monitoring gas chromatography-mass spectrometry

A K Singh et al. J Chromatogr B Biomed Sci Appl. .

Abstract

A broad range of pollutants such as polycyclic aromatic hydrocarbons (PAHs), polychlorinated hydrocarbons (PCHs), polynitrohydrocarbons (PNHs), polychlorinated biphenyls (PCBs) and organochlorine (OCs) insecticides were simultaneously analyzed in spiked soil, water or plasma samples by using gas chromatography-mass spectrometry (GC-MS). Water and plasma samples containing the pollutants were extracted by a solid-phase extraction (SPE) method using florisil columns. The soil samples, fortified with the toxicants, were extracted with water, methanol or dichloromethane (DCM). The water extract was processed by the SPE method. The methanol and DCM samples were dried, dissolved in acetonitrile and subjected to the SPE extraction. The extracted samples were analyzed by GC-MS programmed to monitor selected ions. The deuterium labelled compounds were used as the internal standards. The chromatographic profile of total ions indicated complete separation of some compounds such as isophorone, naphthalene, all PCBs, most OC insecticides and PNHs; high Mr PAHs and some PCHs were partially or incompletely separated. The chromatographic profile of individual ion indicated good separation of each ion. The minimum detection limit ranged from 1 to 4 pg injected when 1 or 2 ions were monitored or from 20 to 200 pg injected when 20 ions were monitored. The SPE method that provided 60-105% recovery of pollutants from water samples, provided only 2-60% recovery from plasma samples. This may be due to the binding of pollutants to plasma proteins. Water recovered 1-30%, while methanol or DCM recovered 65-100% of the pollutants added to the soil samples. The use of internal standards corrected for the loss of pollutants from plasma or soil.

PubMed Disclaimer

Similar articles

Publication types

MeSH terms

LinkOut - more resources