Biomechanical topography of human articular cartilage in the first metatarsophalangeal joint
- PMID: 9553561
Biomechanical topography of human articular cartilage in the first metatarsophalangeal joint
Abstract
The objective of this study was to provide a map of cartilage biomechanical properties, thickness, and histomorphometric characteristics in the human, cadaveric first metatarsophangeal joint, to determine if normal articular cartilage was predisposed topographically to biomechanical mismatches in articulating surfaces. Cartilage intrinsic material properties and thickness were obtained from seven pairs of human, freshly frozen, cadaveric, metatarsophalangeal joints using an automated creep indentation apparatus under conditions of biphasic creep. Eight sites were tested: four on the metatarsal head, two on the proximal phalanx base, and one on each sesamoid bone to obtain the aggregate modulus, Poisson's ratio, permeability, shear modulus, and thickness. Cartilage in the lateral phalanx site of the left metatarsal head had the largest aggregate modulus (1.34 MPa), whereas the softest tissue was found in the right medial sesamoid (0.63 MPa). The medial phalanx region of the right joint was the most permeable (4.56 x 10(-15) meter4/Newton-second), whereas the medial sesamoid articulation of the metatarsal head of the left joint was the least permeable (1.26 x 10(-15) meter4/Newton-second). Material properties and thickness are indicative of the tissue's functional environment. The lack of mismatches in cartilage biomechanical properties of the articulating surfaces found in this study may be supportive of clinical observations that early degenerative changes, in the absence of traumatic events, do not occur at the selected test sites in the human first metatarsophalangeal joint.
Similar articles
-
Comparative study of the intrinsic mechanical properties of the human acetabular and femoral head cartilage.J Orthop Res. 1994 May;12(3):340-9. doi: 10.1002/jor.1100120306. J Orthop Res. 1994. PMID: 8207587
-
[Degenerative cartilage changes in metatarsosesamoidal joint and Scarf procedure results for hallux valgus: a prospective study of 100 cases].Rev Chir Orthop Reparatrice Appar Mot. 2008 Nov;94(7):685-92. doi: 10.1016/j.rco.2007.12.019. Epub 2008 Mar 28. Rev Chir Orthop Reparatrice Appar Mot. 2008. PMID: 18984126 French.
-
Interspecies comparisons of in situ intrinsic mechanical properties of distal femoral cartilage.J Orthop Res. 1991 May;9(3):330-40. doi: 10.1002/jor.1100090304. J Orthop Res. 1991. PMID: 2010837
-
Basic science of articular cartilage and osteoarthritis.Clin Sports Med. 2005 Jan;24(1):1-12. doi: 10.1016/j.csm.2004.08.007. Clin Sports Med. 2005. PMID: 15636773 Review.
-
Material properties and structure-function relationships in the menisci.Clin Orthop Relat Res. 1990 Mar;(252):19-31. Clin Orthop Relat Res. 1990. PMID: 2406069 Review.
Cited by
-
[Biomechanical analysis of ankle-foot complex during a typical Tai Chi movement-Brush Knee and Twist Step].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2021 Feb 25;38(1):97-104. doi: 10.7507/1001-5515.202003003. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2021. PMID: 33899433 Free PMC article. Chinese.
-
Finite element stress analysis of the bearing component and bone resected surfaces for total ankle replacement with different implant material combinations.BMC Musculoskelet Disord. 2022 Jan 19;23(1):70. doi: 10.1186/s12891-021-04982-3. BMC Musculoskelet Disord. 2022. PMID: 35045842 Free PMC article.
-
Joint-specific distance thresholds for patient-specific approximations of articular cartilage modeling in the first ray of the foot.Med Biol Eng Comput. 2014 Sep;52(9):773-9. doi: 10.1007/s11517-014-1179-1. Epub 2014 Aug 7. Med Biol Eng Comput. 2014. PMID: 25100069
-
Can the Entire Function of the Foot Be Concentrated in the Forefoot Area during the Running Stance Phase? A Finite Element Study of Different Shoe Soles.J Hum Kinet. 2023 Nov 28;92:5-17. doi: 10.5114/jhk/174311. eCollection 2024 Apr. J Hum Kinet. 2023. PMID: 38736608 Free PMC article.
-
Effect of Different Protection on Lateral Ankle during Landing: An Instantaneous Impact Analysis.Bioengineering (Basel). 2022 Dec 27;10(1):34. doi: 10.3390/bioengineering10010034. Bioengineering (Basel). 2022. PMID: 36671606 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources