Metabolite analysis of [11C]flumazenil in human plasma: assessment as the standardized value for quantitative PET studies
- PMID: 9559964
- DOI: 10.1007/BF03165418
Metabolite analysis of [11C]flumazenil in human plasma: assessment as the standardized value for quantitative PET studies
Abstract
Analysis of carbon-11 labeled metabolites in plasma was carried out during positron emission tomography (PET) studies with a central benzodiazepine receptor ligand [11C]flumazenil ([11C]FMZ) in 24 human subjects (14-76 y.o.) including five normal volunteers and 19 patients with neurological disorders. Arterial plasma samples were obtained at 3, 5, 10, 15, 20, 30 and 60 min after i.v. injection of the tracer, and were analyzed by high-performance liquid chromatography. The rate of plasma [11C]FMZ degradation was associated with a large individual variation, but no significant difference was found in the degradation of [11C]FMZ either between male and female, young and old, or between normal subjects and patient groups. When the mean fraction of unchanged [11C]FMZ at each time point was used instead of individually measured metabolite data for the arterial input function, as much as a 30% error occurred in the distribution volume of the [11C]FMZ binding in the brain. These results indicate that the mean percentage of unchanged [11C]FMZ fraction in subjects cannot be used as the standardized value, and that the analysis of metabolites in plasma is necessary to determine the exact arterial input function for quantitative PET measurement.
Similar articles
-
Intrasubject correlation between static scan and distribution volume images for [11C]flumazenil PET.Ann Nucl Med. 2000 Jun;14(3):193-8. doi: 10.1007/BF02987859. Ann Nucl Med. 2000. PMID: 10921484
-
Simple analytic method of 11C-flumazenil metabolite in blood.J Nucl Med. 2003 Mar;44(3):417-21. J Nucl Med. 2003. PMID: 12621009
-
[11C]flumazenil PET: activity images versus parametric images for the detection of neocortical epileptic foci.J Nucl Med. 1999 Dec;40(12):1985-91. J Nucl Med. 1999. PMID: 10616875
-
Positron emission tomography in partial epilepsies: the clinical point of view.Nucl Med Commun. 1998 Dec;19(12):1123-6. doi: 10.1097/00006231-199812000-00003. Nucl Med Commun. 1998. PMID: 9885801 Review.
-
Positron emission tomography receptor studies.Adv Neurol. 1999;79:893-9. Adv Neurol. 1999. PMID: 10514872 Review.
Cited by
-
Dealing with PET radiometabolites.EJNMMI Res. 2020 Sep 23;10(1):109. doi: 10.1186/s13550-020-00692-4. EJNMMI Res. 2020. PMID: 32997213 Free PMC article. Review.
-
Estimating neurotransmitter kinetics with ntPET: a simulation study of temporal precision and effects of biased data.Neuroimage. 2008 Feb 1;39(3):1162-79. doi: 10.1016/j.neuroimage.2007.09.046. Epub 2007 Oct 5. Neuroimage. 2008. PMID: 18023364 Free PMC article.
-
Improved detection and measurement of low levels of [18F]fluoride metabolized from [18F]-labeled pyrimidine nucleoside analogues in biological samples.Nucl Med Biol. 2011 Nov;38(8):1129-34. doi: 10.1016/j.nucmedbio.2011.05.008. Epub 2011 Jul 8. Nucl Med Biol. 2011. PMID: 21741850 Free PMC article.
-
Plasma radiometabolite correction in dynamic PET studies: Insights on the available modeling approaches.J Cereb Blood Flow Metab. 2016 Feb;36(2):326-39. doi: 10.1177/0271678X15610585. Epub 2015 Oct 14. J Cereb Blood Flow Metab. 2016. PMID: 26661202 Free PMC article. Review.
-
Image-derived input function for brain PET studies: many challenges and few opportunities.J Cereb Blood Flow Metab. 2011 Oct;31(10):1986-98. doi: 10.1038/jcbfm.2011.107. Epub 2011 Aug 3. J Cereb Blood Flow Metab. 2011. PMID: 21811289 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources