Detection of myocardial perfusion defects by contrast echocardiography in the setting of acute myocardial ischemia with residual antegrade flow
- PMID: 9560746
- DOI: 10.1016/s0894-7317(98)70084-7
Detection of myocardial perfusion defects by contrast echocardiography in the setting of acute myocardial ischemia with residual antegrade flow
Abstract
Although myocardial contrast echocardiography accurately demarcates area at risk during total coronary occlusion, the ability of MCE to delineate area at risk in the presence of residual antegrade flow is unknown. We hypothesized that perfusion defects in myocardial segments supplied by severe coronary stenoses with residual antegrade flow could be detected by MCE using intravenous FS069. We studied 13 open-chest dogs using an intravenous injection of FS069 during intermittent harmonic imaging. Images were collected at baseline, during acute ischemia with residual antegrade flow, physiologic hyperemia (release of stenosis), and total coronary occlusion. Regional myocardial blood flow was assessed using colored microspheres. MCE risk area during acute ischemia with residual antegrade flow and total occlusion was planimetered and compared with pathologic risk area (area unstained by monastral blue). Background-subtracted peak videointensity in the risk area was assessed for all flow states. Regional myocardial blood flow confirmed expected flow states, being significantly greater during physiologic hyperemia (4.16 +/- 1.22 ml/min/g) than at baseline (0.71 +/- 0.19 ml/min/g) and significantly diminished during coronary stenosis with residual antegrade flow (0.20 +/- 0.16 ml/min/g) and total occlusion (0.09 +/- 0.06 ml/min/g; p < 0.0001). Myocardial risk area by MCE during coronary stenosis with residual antegrade flow correlated well with pathologic risk area determined by monastral blue staining (r = 0.86). Peak videointensity during coronary stenosis (111 +/- 27) was significantly less than at baseline (157 +/- 50) but greater than during total occlusion (81 +/- 34; p < 0.0001). In conclusion, intravenous FS069 in conjunction with intermittent harmonic imaging delineates area at risk in ischemic myocardium supplied by a coronary stenoses with residual antegrade flow. The presence of a perfusion defect on MCE does not necessarily imply that the coronary artery is totally occluded.
Similar articles
-
Evaluation of dynamic changes in microvascular flow during ischemia-reperfusion by myocardial contrast echocardiography.J Am Coll Cardiol. 1998 Oct;32(4):1096-101. doi: 10.1016/s0735-1097(98)00349-0. J Am Coll Cardiol. 1998. PMID: 9768738
-
Detection of coronary stenoses and quantification of the degree and spatial extent of blood flow mismatch during coronary hyperemia with myocardial contrast echocardiography.Circulation. 1995 Feb 1;91(3):821-30. doi: 10.1161/01.cir.91.3.821. Circulation. 1995. PMID: 7828311
-
Myocardial contrast echocardiography: reliable, safe, and efficacious myocardial perfusion assessment after intravenous injections of a new echocardiographic contrast agent.Am Heart J. 1996 Oct;132(4):871-81. doi: 10.1016/s0002-8703(96)90324-5. Am Heart J. 1996. PMID: 8831379
-
Myocardial contrast echocardiography in the assessment of patients with chronic coronary artery disease.Echocardiography. 2003 Aug;20 Suppl 1:S31-42. doi: 10.1046/j.1540-8175.20.s1.5.x. Echocardiography. 2003. PMID: 23573623 Review.
-
Italian Society of Cardiovascular Echography (SIEC) Consensus Conference on the state of the art of contrast echocardiography.Ital Heart J. 2004 Apr;5(4):309-34. Ital Heart J. 2004. PMID: 15185894 Review.
Cited by
-
Spatial distribution of right ventricular perfusion abnormalities following acute right coronary artery occlusion: a study by myocardial contrast echocardiography and blue dye staining.Int J Cardiovasc Imaging. 2005 Dec;21(6):599-607. doi: 10.1007/s10554-005-2371-z. Int J Cardiovasc Imaging. 2005. PMID: 16322918
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources