A dynamic analysis of glenohumeral motion after simulated capsulolabral injury. A cadaver model
- PMID: 9563376
- DOI: 10.2106/00004623-199804000-00003
A dynamic analysis of glenohumeral motion after simulated capsulolabral injury. A cadaver model
Abstract
We used a dynamic shoulder-testing apparatus and nine fresh-frozen, entire upper extremities from cadavera to evaluate the effects of varying degrees of capsulolabral injury on the kinematics of the glenohumeral joint during abduction in the scapular plane and external rotation. Joint kinematics were recorded with use of a six-degrees-of-freedom magnetic tracking device before and after the creation of each capsulolabral lesion in a progressive manner. Dislocation did not occur after simulation of a large Bankart lesion or even after sectioning of the anterior aspect of the joint capsule. However, division of the entire joint capsule (that is, both the anterior aspect and the posterior aspect) resulted in a significant increase (p < 0.05) in posterior translation during abduction in the scapular plane, and two of the nine shoulders dislocated posteriorly. External rotation of the abducted extremity produced no increase in anterior or posterior translation.
Similar articles
-
Effect of glenohumeral position on contact pressure between the capsulolabral complex and the glenoid in free ALPSA and Bankart lesions.Knee Surg Sports Traumatol Arthrosc. 2016 Feb;24(2):350-6. doi: 10.1007/s00167-015-3962-4. Epub 2016 Jan 2. Knee Surg Sports Traumatol Arthrosc. 2016. PMID: 26724827
-
Anterior capsulolabral lesions combined with supraspinatus tendon tears: biomechanical effects of the pathologic condition and repair in human cadaveric shoulders.Arthroscopy. 2013 Sep;29(9):1492-7. doi: 10.1016/j.arthro.2013.05.031. Epub 2013 Jul 30. Arthroscopy. 2013. PMID: 23910002
-
[Biomechanical tests for type II SLAP lesions of the shoulder joint before and after arthroscopic repair].Orthopade. 2003 Jul;32(7):600-7. doi: 10.1007/s00132-003-0495-1. Orthopade. 2003. PMID: 12883759 German.
-
The effect of articular malposition after total shoulder arthroplasty on glenohumeral translations, range of motion, and subacromial impingement.J Shoulder Elbow Surg. 2001 Sep-Oct;10(5):399-409. doi: 10.1067/mse.2001.116871. J Shoulder Elbow Surg. 2001. PMID: 11641695
-
The effect of the remplissage procedure on shoulder stability and range of motion: an in vitro biomechanical assessment.J Bone Joint Surg Am. 2012 Jun 6;94(11):1003-12. doi: 10.2106/JBJS.J.01956. J Bone Joint Surg Am. 2012. PMID: 22637206
Cited by
-
Effect of rotator cuff muscle activation on glenohumeral kinematics: A cadaveric study.J Biomech. 2020 May 22;105:109798. doi: 10.1016/j.jbiomech.2020.109798. Epub 2020 Apr 18. J Biomech. 2020. PMID: 32423544 Free PMC article.
-
The development and evaluation of an in-vitro shoulder simulator with active muscle simulation.Sci Rep. 2023 Mar 17;13(1):4423. doi: 10.1038/s41598-023-31200-y. Sci Rep. 2023. PMID: 36932123 Free PMC article.
-
Moment arms of the muscles crossing the anatomical shoulder.J Anat. 2008 Oct;213(4):383-90. doi: 10.1111/j.1469-7580.2008.00965.x. Epub 2008 Aug 6. J Anat. 2008. PMID: 18691376 Free PMC article.
-
Verification of Shoulder External Rotators Strength Measurement Using a Suspension Scale.Cureus. 2022 Jun 20;14(6):e26106. doi: 10.7759/cureus.26106. eCollection 2022 Jun. Cureus. 2022. PMID: 35875292 Free PMC article.
-
Graft Tensioning in Superior Capsular Reconstruction Improves Glenohumeral Joint Kinematics in Massive Irreparable Rotator Cuff Tears: A Biomechanical Study of the Influence of Superior Capsular Reconstruction on Dynamic Shoulder Abduction.Orthop J Sports Med. 2020 Oct 6;8(10):2325967120957424. doi: 10.1177/2325967120957424. eCollection 2020 Oct. Orthop J Sports Med. 2020. PMID: 33088839 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical