Complications of intra-aortic balloon counterpulsation. The role of catheter size and duration of support in a multivariate analysis of risk
- PMID: 9568450
- DOI: 10.1053/euhj.1997.0802
Complications of intra-aortic balloon counterpulsation. The role of catheter size and duration of support in a multivariate analysis of risk
Abstract
Aims: The aim of this study was to assess the risk of intra-aortic balloon counterpulsation and to identify clinical and procedural variables that would predict complications.
Methods and results: We analysed 381 consecutive patients who were treated between 1977 and 1995 at our catheterization laboratory and/or medical intensive care unit. The complications considered relevant were limb ischaemia requiring catheter removal, vascular injury, bleeding requiring transfusion, embolic events, and infection. In eight patients the balloon could not be inserted. The rate of complications for the remaining 373 patients was 12.9%. Between 1977 and 1980, surgical insertion was performed using a 12 French catheter with a complication rate of 30.4% (seven of 23 patients). Percutaneous implantation, performed after 1981, had an overall complication rate of 11.7% (41 of 350 patients). Using thinner catheters for percutaneous placement was associated with a reduction in the rate of complications, from 20.7% (17 of 82 patients) for 12 French catheters to 9.9% (10 of 101 patients) for 10.5 French catheters (P = 0.04), and 8.4% (14 of 167 patients) for 9.5 French catheters (P = 0.006). Multivariate logistic regression analysis identified duration of counterpulsation > 48 h (odds ratio 3.6), catheter size (odds ratio 3.4 for 12 French catheters), peripheral vascular disease (odds ratio 2.7), and shock (odds ratio 2.0) as independent risk factors for counterpulsation-associated complications. When considering 9.5 French catheters only (167 patients, all after 1992), the sole remaining independent risk factor was duration of counterpulsation > 48 h (odds ratio 3.8). Those patients with 9.5 French catheters in whom counterpulsation did not exceed 48 h had a low complication rate of 3.9%.
Conclusion: The rate of percutaneous intra-aortic balloon counterpulsation complications was thus significantly reduced by employing thinner catheters. It was at an acceptable level for 9.5 French catheters, where a long duration of counterpulsation emerged as the most significant factor associated with complications. Whether using even thinner catheters in combination with a sheathless implantation technique further minimizes the risk of counterpulsation remains to be seen.
Similar articles
-
In-hospital complications of percutaneous intraaortic balloon counterpulsation.Angiology. 2003 Sep-Oct;54(5):577-85. doi: 10.1177/000331970305400507. Angiology. 2003. PMID: 14565633
-
Complications associated with percutaneous placement of intra-aortic balloon counterpulsation: can unsheathed insertion reduce limb ischaemia?Acta Cardiol. 2000 Jun;55(3):175-9. doi: 10.2143/AC.55.3.2005736. Acta Cardiol. 2000. PMID: 10902042
-
Complications associated with percutaneous placement and use of intraaortic balloon counterpulsation.Am J Cardiol. 1993 Feb 1;71(4):328-32. doi: 10.1016/0002-9149(93)90800-r. Am J Cardiol. 1993. PMID: 8427177
-
Intra-aortic balloon counterpulsation complicated by limb ischaemia: a reflective commentary.Nurs Crit Care. 2006 Nov-Dec;11(6):297-304. doi: 10.1111/j.1478-5153.2006.00187.x. Nurs Crit Care. 2006. PMID: 17883678 Review.
-
Preoperative intra-aortic counterpulsation in high-risk patients undergoing cardiac surgery: a meta-analysis of randomized controlled trials†.Eur J Cardiothorac Surg. 2016 Jan;49(1):5-17. doi: 10.1093/ejcts/ezv258. Epub 2015 Aug 5. Eur J Cardiothorac Surg. 2016. PMID: 26245629 Review.
Cited by
-
Encouraging survival rates in patients with acute myocardial infarction treated with an intra-aortic balloon pump.Neth Heart J. 2011 Mar;19(3):112-118. doi: 10.1007/s12471-010-0066-0. Epub 2011 Jan 18. Neth Heart J. 2011. PMID: 21475411 Free PMC article.
-
Continuous internal counterpulsation as a bridge to recovery in acute and chronic heart failure.World J Transplant. 2016 Mar 24;6(1):115-24. doi: 10.5500/wjt.v6.i1.115. World J Transplant. 2016. PMID: 27011909 Free PMC article. Review.
-
Mechanical Circulatory Assist Devices: Available Modalities and Review of Literature.Heart Views. 2020 Oct-Dec;21(4):269-275. doi: 10.4103/HEARTVIEWS.HEARTVIEWS_92_20. Epub 2021 Jan 14. Heart Views. 2020. PMID: 33986926 Free PMC article. Review.
-
[Reperfusion therapy and mechanical circulatory support in patients in cardiogenic shock].Herz. 1999 Oct;24(6):448-64. doi: 10.1007/BF03044431. Herz. 1999. PMID: 10546149 Review. German.
-
Superior performance of a paraaortic counterpulsation device compared to the intraaortic balloon pump.World J Surg. 2003 Dec;27(12):1311-6. doi: 10.1007/s00268-003-6928-5. Epub 2003 Nov 5. World J Surg. 2003. PMID: 14586569