Dimensional stability and detail reproduction of irreversible hydrocolloid and elastomeric impressions disinfected by immersion
- PMID: 9576321
- DOI: 10.1016/s0022-3913(98)70160-x
Dimensional stability and detail reproduction of irreversible hydrocolloid and elastomeric impressions disinfected by immersion
Abstract
Statement of problem: Because irreversible hydrocolloid impressions imbibe blood and saliva, immersion rather than spray disinfection may be more effective. Polyether has been shown to be dimensionally sensitive to immersion disinfection.
Purpose: The aim of this study was to determine whether irreversible hydrocolloid and polyether impressions could be disinfected by immersion without sacrificing accuracy and surface quality.
Material and methods: Impressions were made of a master mandibular arch containing a crown preparation. Changes between the master and working casts were assessed. Irreversible hydrocolloids (Jeltrate; Palgaflex), a polyether (Impregum F), and an addition silicone (President) were used. Disinfectants were an iodophor (Biocide), a glyoxal glutaraldehyde (Impresept de), and a phenol glutaraldehyde (Sporicidin). The control was without disinfection. Casts were formed in Type IV gypsum. The roughness of working dies was also recorded and an analysis of variance was used for statistical evaluation. Results. Casts from disinfected irreversible hydrocolloid and elastomeric impressions maintained accuracy for anteroposterior and cross arch dimensions where differences from the master was less than 0.1%. Buccolingual and mesiodistal dimensions of working dies (disinfected and control) were 6 to 8 microm larger than the master for addition silicones and 11 to 16 pm for polyethers. The occlusogingival dimension of dies for control and disinfected polyether was 9 pm longer than the master compared with -3 microm for addition silicone. The range of mean surface roughness of working dies made from irreversible hydrocolloids was 1.4 to 1.7 microm and ranged from 0.5 to 0.7 microm for elastomeric impressions. Conclusion. Immersion disinfection of Jeltrate material with iodophor and Palgaflex material with glyoxal glutaraldehyde produced casts and dies as accurate as the control. Control and disinfected elastomeric impression produced dies as clinically accurate and smooth as the master. Disinfection of irreversible hydrocolloid impressions with the glyoxal and phenol glutaraldehyde produced a surface smoother than controls.
Similar articles
-
Accuracy of a new ring-opening metathesis elastomeric dental impression material with spray and immersion disinfection.J Prosthet Dent. 2010 Jan;103(1):23-30. doi: 10.1016/S0022-3913(09)60210-9. J Prosthet Dent. 2010. PMID: 20105678
-
Accuracy of newly formulated fast-setting elastomeric impression materials.J Prosthet Dent. 2005 Jun;93(6):530-9. doi: 10.1016/j.prosdent.2005.03.007. J Prosthet Dent. 2005. PMID: 15942613
-
Comparison of dimensional accuracy of four different die materials before and after disinfection of the impression: an in vitro study.J Contemp Dent Pract. 2013 Jul 1;14(4):668-74. doi: 10.5005/jp-journals-10024-1383. J Contemp Dent Pract. 2013. PMID: 24309347
-
Disinfection efficacy of sodium hypochlorite and glutaraldehyde and their effects on the dimensional stability and surface properties of dental impressions: a systematic review.PeerJ. 2023 Feb 20;11:e14868. doi: 10.7717/peerj.14868. eCollection 2023. PeerJ. 2023. PMID: 36846444 Free PMC article.
-
A survey of the methods of disinfection of dental impressions used in dental hospitals in the United Kingdom.Br Dent J. 1996 May 25;180(10):369-75. doi: 10.1038/sj.bdj.4809092. Br Dent J. 1996. PMID: 8652299 Review.
Cited by
-
Comparative evaluation of the effect of electrolyzed oxidizing water on surface detail reproduction, dimensional stability and Surface texture of poly vinyl siloxane impressions.J Indian Prosthodont Soc. 2019 Jan-Mar;19(1):33-41. doi: 10.4103/jips.jips_72_18. J Indian Prosthodont Soc. 2019. PMID: 30745752 Free PMC article.
-
A comparative evaluation of the dimensional stability of three different elastomeric impression materials after autoclaving - an invitro study.J Clin Diagn Res. 2014 Oct;8(10):ZC48-50. doi: 10.7860/JCDR/2014/9768.5036. Epub 2014 Oct 20. J Clin Diagn Res. 2014. PMID: 25478447 Free PMC article.
-
Use of Clinical UV Chamber to Disinfect Dental Impressions: A Comparative Study.J Clin Diagn Res. 2015 Aug;9(8):ZC67-70. doi: 10.7860/JCDR/2015/14025.6353. Epub 2015 Aug 1. J Clin Diagn Res. 2015. PMID: 26436051 Free PMC article.
-
In vivo Study of the Accuracy of Dual-arch Impressions.J Int Oral Health. 2014 Jun;6(3):50-5. Epub 2014 Jun 26. J Int Oral Health. 2014. PMID: 25083032 Free PMC article.
-
Dimensional changes of alginate dental impression materials.J Mater Sci Mater Med. 2006 Dec;17(12):1205-10. doi: 10.1007/s10856-006-0593-9. J Mater Sci Mater Med. 2006. PMID: 17143750
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials