Intubation via the LMA using a Cook retrograde intubation kit
- PMID: 9579265
- DOI: 10.1007/BF03012912
Intubation via the LMA using a Cook retrograde intubation kit
Abstract
Purpose: We report two cases of difficult intubation where a laryngeal mask airway (LMA) was used and changed to a conventional endotracheal tube using a retrograde intubation set.
Clinical findings: In two patients, following induction of anaesthesia, the trachea could not be intubated in the conventional fashion with a blade. In both patients an LMA was inserted to achieve an airway. In both patients intubation with a conventional endotracheal tube was required. A Cook Retrograde Intubation Kit and fibreoptic bronchoscope were used to change the LMA to conventional endotracheal tube without problems.
Conclusion: The Cook retrograde intubation allows an LMA to be replaced with an endotracheal tube with an ID greater than 6 mm with a #3 or 7 mm with a #5 LMA. This technique places an exchange stylet into the airway which is superior to a conventional guidewire. This method allows the airway to be maintained until the LMA is exchanged with an endotracheal tube. Anaesthesia may be maintained and the airway instrumented without difficulty using this technique.
Similar articles
-
[Fiber optic intubation using a modified laryngeal mask. Report of experiences with use in 105 patients].Anasthesiol Intensivmed Notfallmed Schmerzther. 1997 Mar;32(3):164-8. doi: 10.1055/s-2007-995031. Anasthesiol Intensivmed Notfallmed Schmerzther. 1997. PMID: 9190164 German.
-
Intubation via LMA in pediatric patients with difficult airways.Can J Anaesth. 1999 Sep;46(9):891-3. doi: 10.1007/BF03012981. Can J Anaesth. 1999. PMID: 10490160
-
Laryngo-pharyngeal complaints following laryngeal mask airway and endotracheal intubation.J Clin Anesth. 1997 Feb;9(1):42-7. doi: 10.1016/S0952-8180(96)00209-7. J Clin Anesth. 1997. PMID: 9051545 Clinical Trial.
-
The Fastrach Intubating Laryngeal Mask Airway: an overview and update.Can J Anaesth. 2010 Jun;57(6):588-601. doi: 10.1007/s12630-010-9272-x. Epub 2010 Jan 29. Can J Anaesth. 2010. PMID: 20112078 Review.
-
The laryngeal mask airway. Safety, efficacy, and current use.Am J Anesthesiol. 1995 Mar-Apr;22(2):65-9. Am J Anesthesiol. 1995. PMID: 10150237 Review.
Cited by
-
Successful wire-guided fiberoptic nasotracheal intubation in a patient with hemifacial microsomia - A case report.Anesth Pain Med (Seoul). 2020 Jan 31;15(1):73-77. doi: 10.17085/apm.2020.15.1.73. Anesth Pain Med (Seoul). 2020. PMID: 33329793 Free PMC article.
-
Is central-line guidewire sufficient for retrograde intubation?Indian J Anaesth. 2011 May;55(3):321. doi: 10.4103/0019-5049.82671. Indian J Anaesth. 2011. PMID: 21808422 Free PMC article. No abstract available.
-
[Intubation with a tube exchanger on an intubation trainer. Influence of tube tip position on successful intubation].Anaesthesist. 2014 Jul;63(7):563-7. doi: 10.1007/s00101-014-2342-7. Epub 2014 Jul 2. Anaesthesist. 2014. PMID: 24981151 German.
-
Retrograde intubation in a dog with severe temporomandibular joint ankylosis: case report.BMC Vet Res. 2018 Mar 27;14(1):118. doi: 10.1186/s12917-018-1439-7. BMC Vet Res. 2018. PMID: 29587754 Free PMC article.
-
Does the site of anterior tracheal puncture affect the success rate of retrograde intubation? A prospective, manikin-based study.Anesthesiol Res Pract. 2013;2013:354317. doi: 10.1155/2013/354317. Epub 2013 Jun 26. Anesthesiol Res Pract. 2013. PMID: 23878535 Free PMC article.