Evaluation of a digital radiography to estimate working length
- PMID: 9580242
- DOI: 10.1016/s0099-2399(97)80183-5
Evaluation of a digital radiography to estimate working length
Abstract
The working lengths obtained with different methods in single-rooted teeth were compared. An endodontic rule in millimeters and calipers was used as a direct method of measurement (on endodontic files). As indirect methods, measurements were taken from conventional x-rays with calipers and with a digital radiological measurement system. No statistically significant differences were obtained between the direct and indirect methods. Three vertical angulations were taken for the indirect methods (0 degree, 15 degrees, and 30 degrees). No significant differences were found between results for the two indirect methods versus the standard method except for the 30 degrees angulation, which resulted in an impression of a shortened image of about 1.5 mm when using the indirect methods (significance level: alpha = 0.05).
Similar articles
-
Evaluation of a digital measurement tool to estimate working length in endodontics.J Contemp Dent Pract. 2001 Feb 15;2(1):24-30. J Contemp Dent Pract. 2001. PMID: 12167941
-
Canal length evaluation of curved canals by direct digital or conventional radiography.Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2002 Jan;93(1):88-91. doi: 10.1067/moe.2002.119466. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2002. PMID: 11805781
-
Working length in root canal fillings.N Y State Dent J. 1993 Nov;59(9):41-3. N Y State Dent J. 1993. PMID: 8247456 No abstract available.
-
Endodontic working length determination--where does it end?Gen Dent. 1999 May-Jun;47(3):281-6; quiz 287-8. Gen Dent. 1999. PMID: 10687440 Review.
-
Problem solving in endodontic working-length determination.Compend Contin Educ Dent. 1995 Mar;16(3):288, 290, 293-4 passim; quiz 304. Compend Contin Educ Dent. 1995. PMID: 8935000 Review.
Cited by
-
The accuracy of digital radiography in orthopaedic applications.Clin Orthop Relat Res. 2011 Jun;469(6):1781-4. doi: 10.1007/s11999-010-1628-6. Epub 2010 Oct 23. Clin Orthop Relat Res. 2011. PMID: 20972654 Free PMC article.
-
Comparison of radiographic measurements obtained with conventional and indirect digital imaging during endodontic treatment.J Appl Oral Sci. 2008 Mar-Apr;16(2):167-70. doi: 10.1590/s1678-77572008000200016. J Appl Oral Sci. 2008. PMID: 19089211 Free PMC article.
-
Effect of digital noise reduction on the accuracy of endodontic file length determination.Imaging Sci Dent. 2013 Sep;43(3):185-90. doi: 10.5624/isd.2013.43.3.185. Epub 2013 Sep 23. Imaging Sci Dent. 2013. PMID: 24083212 Free PMC article.
-
In vivo accuracy of conventional and digital radiographic methods in confirming root canal working length determination by Root ZX.J Appl Oral Sci. 2012 Sep-Oct;20(5):522-5. doi: 10.1590/s1678-77572012000500005. J Appl Oral Sci. 2012. PMID: 23138737 Free PMC article.
-
A comparative evaluation of working length with digital radiography and third generation apex locator (ProPex) in the presence of various intracanal irrigants: An in vivo/ex vivo study.Dent Res J (Isfahan). 2014 Jan;11(1):56-60. Dent Res J (Isfahan). 2014. PMID: 24688561 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials