Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1998 May;101(6):1675-83; discussion 1684.
doi: 10.1097/00006534-199805000-00040.

A 6-year experience with the use of expanded polytetrafluoroethylene in rhinoplasty

Affiliations

A 6-year experience with the use of expanded polytetrafluoroethylene in rhinoplasty

K Conrad et al. Plast Reconstr Surg. 1998 May.

Abstract

To date, there are few published large series within the literature on the use of expanded polytetrafluoroethylene (Gore-Tex) in rhinoplasty. This retrospective study, based on chart and photographic reviews, serves to contribute a 6-year experience (mean patient follow-up period, 17.5 months) with the alloplast in nasal surgery amassed by one surgeon. The same technique was used in all the 189 patients reviewed, who received 211 procedures. The 189 patients, 44 male and 145 female and from 15 to 70 years of age, were reviewed 3 months to 6 years after Gore-Tex implantation rhinoplasties. The results were assessed according to the follow-up notes in the chart reflecting patients' and surgeon's comments and full preoperative and postoperative photographic documentation. Patient satisfaction was expressed with respect to aesthetic and functional outcome in all cases. Patient impressions were verified by critical assessment during follow-up examination. The implants showed excellent stability and tissue tolerance. Complications requiring removal occurred in 2.7 percent of implants placed. The authors are of the opinion that, in rhinoplasty, with the exception of the nasal tip, columella, or problems in which corrections would require rigidity of the grafted or implanted material, the Gore-Tex alloplast is an excellent alternative to autografts. Nasal tip or columellar sites do not render adequate soft-tissue cover, allowing the implant to rest close to the surgical incision. Because this creates additional risk of implant extrusion, such locations were avoided in the series of patients presented.

PubMed Disclaimer

Substances

LinkOut - more resources