Sonographic evaluation of intervillous flow in early pregnancy: use of echo-enhancement agents
- PMID: 9589145
- DOI: 10.1046/j.1469-0705.1998.11030204.x
Sonographic evaluation of intervillous flow in early pregnancy: use of echo-enhancement agents
Abstract
The uteroplacental circulation of the cynomolgus monkey was examined in early pregnancy using a high-resolution ultrasound scanner. Intravenous injection of an echo-contrast agent, Albunex (sonicated albumin), was used to enhance the color Doppler images obtained. The flow of blood into and out of the intervillous compartment was readily assessed and quantified using pulsed and color Doppler. Flow within the intracotyledonary space was pulsatile and indicative of a low-resistance system. Flow within the decidual veins was non-pulsatile. The use of echo-contrast agents may assist in the determination of intervillous flow in human pregnancy at a correspondingly early stage.
Similar articles
-
[Study of intervillous blood circulation using color and pulsed doppler ultrasound].Lijec Vjesn. 1999 Jun;121(6):194-8. Lijec Vjesn. 1999. PMID: 10494155 Review. Croatian.
-
Contrast sonography, video densitometry and intervillous blood flow: a pilot project.Placenta. 2006 Jun-Jul;27(6-7):719-26. doi: 10.1016/j.placenta.2005.07.007. Epub 2005 Sep 12. Placenta. 2006. PMID: 16157372
-
Intervillous circulation in the first trimester: the phantom of the color Doppler obstetric opera.Ultrasound Obstet Gynecol. 1996 Aug;8(2):73-6. doi: 10.1046/j.1469-0705.1996.08020073.x. Ultrasound Obstet Gynecol. 1996. PMID: 8883306 Review. No abstract available.
-
Intervillous blood flow in the third trimester gravid rhesus monkey (Macaca mulatta): use of sonographic contrast agent and harmonic imaging.Placenta. 2001 Feb-Mar;22(2-3):200-5. doi: 10.1053/plac.2000.0605. Placenta. 2001. PMID: 11170824
-
[Hemodynamic evaluation in early pregnancy--intervillous circulation. Literature review--part one].Akush Ginekol (Sofiia). 2007;46(6):15-20. Akush Ginekol (Sofiia). 2007. PMID: 17974166 Review. Bulgarian. No abstract available.
Cited by
-
Safety of contrast-enhanced ultrasound using microbubbles in human pregnancy: A scoping review.Ultraschall Med. 2025 Jun;46(3):259-269. doi: 10.1055/a-2351-0747. Epub 2024 Jun 24. Ultraschall Med. 2025. PMID: 38914129 Free PMC article.
-
Real-time placental perfusion on contrast-enhanced ultrasound and parametric imaging analysis in rats at different gestation time and different portions of placenta.PLoS One. 2013;8(4):e58986. doi: 10.1371/journal.pone.0058986. Epub 2013 Apr 1. PLoS One. 2013. PMID: 23560042 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources