Comparison of low and high dose corticotropin stimulation tests in patients with pituitary disease
- PMID: 9589655
- DOI: 10.1210/jcem.83.5.4831
Comparison of low and high dose corticotropin stimulation tests in patients with pituitary disease
Abstract
Tetracosactin [corticotropin-(1-24)] is used for clinical testing of adrenocortical responsiveness. The usual dose [high dose test (HDT)] is 250 micrograms. With this test, patients with mild secondary adrenal insufficiency are usually not identified, thus putting them at risk of an adrenal crisis in stressful situations. It was recently reported that a tetracosactin test with approximately 1 micrograms [low dose test (LDT)] identifies patients with mild forms of pituitary-adrenal insufficiency. We performed both the HDT and the LDT in 35 control subjects and in 44 patients with pituitary disease, mostly pituitary tumors. In these patients, more sensitive reference tests for evaluating the pituitary-adrenal axis (insulin-induced hypoglycemia, metyrapone, and CRH tests) were also performed. In the HDT, plasma cortisol was measured 30 and 60 min after tetracosactin injection; in the LDT (0.5 microgram/m2 body surface area), plasma cortisol was measured 20, 30, 40, 50, and 60 min postinjection. In 6 control subjects, tetracosactin plasma levels were also measured after injection. In the HDT, the correlation between 30 and 60 min cortisol levels was extremely high (r = 0.991; P < 0.0001), but the correlation of the LDT with the HDT at 30 min was also highly significant (r = 0.948; P < 0.0001). The lower normal limit of cortisol responses (means of controls minus 2 SD) at 30 min was lower in the LDT by 3.1 micrograms/dL (85 nmol/L) than in the HDT. Compared with the reference tests, the diagnostic sensitivities of the HDT and the LDT were almost identical. Both tests identified patients with moderately to severely pathological insulin and metyrapone tests, but not those with slightly pathological reference tests. In the HDT, plasma tetracosactin rose to more than 60,000 pg/mL shortly after injection. In the LDT, it rose to 1,900 pg/mL. Both concentrations stimulate cortisol (supra-) maximally. Together, these data show that in pituitary disorders the results of the LDT and the HDT are almost identical. Plasma tetracosactin levels in the LDT still rise to levels that maximally stimulate the adrenal. Tetracosactin testing with low or high doses cannot generally replace the more expensive and cumbersome insulin or metyrapone tests.
Comment in
-
Comments on the comparison of low and high dose corticotropin stimulation tests in patients with pituitary disease.J Clin Endocrinol Metab. 1998 Dec;83(12):4530; author reply 4532-3. doi: 10.1210/jcem.83.12.5322-3. J Clin Endocrinol Metab. 1998. PMID: 9851806 No abstract available.
-
Comment on the low-dose corticotropin stimulation test is more sensitive than the high-dose test.J Clin Endocrinol Metab. 1998 Dec;83(12):4530-1; author reply 4532-3. doi: 10.1210/jc.83.12.4530-a. J Clin Endocrinol Metab. 1998. PMID: 9851807 No abstract available.
-
Commentary to the article: comparison of low and high dose corticotropin stimulation tests in patients with pituitary disease.J Clin Endocrinol Metab. 1998 Dec;83(12):4531-3. doi: 10.1210/jcem.83.12.5322-5. J Clin Endocrinol Metab. 1998. PMID: 9851808 No abstract available.
-
About the use and misuse of an ACTH 1-39 radioimmunoassay to measure ACTH 1-24.J Clin Endocrinol Metab. 1999 Feb;84(2):824-5. doi: 10.1210/jcem.84.2.5472-10. J Clin Endocrinol Metab. 1999. PMID: 10022466 No abstract available.
Similar articles
-
Comparison of adrenocorticotropin (ACTH) stimulation tests and insulin hypoglycemia in normal humans: low dose, standard high dose, and 8-hour ACTH-(1-24) infusion tests.J Clin Endocrinol Metab. 1999 Oct;84(10):3648-55. doi: 10.1210/jcem.84.10.6062. J Clin Endocrinol Metab. 1999. PMID: 10523009 Clinical Trial.
-
Profile, mean residence time of ACTH and cortisol responses after low and standard ACTH tests in healthy volunteers.Clin Endocrinol (Oxf). 2006 Sep;65(3):346-51. doi: 10.1111/j.1365-2265.2006.02602.x. Clin Endocrinol (Oxf). 2006. PMID: 16918954 Clinical Trial.
-
Establishment of reference values for standard dose short synacthen test (250 microgram), low dose short synacthen test (1 microgram) and insulin tolerance test for assessment of the hypothalamo-pituitary-adrenal axis in normal subjects.Clin Endocrinol (Oxf). 2000 Aug;53(2):199-204. doi: 10.1046/j.1365-2265.2000.01028.x. Clin Endocrinol (Oxf). 2000. PMID: 10931101 Clinical Trial.
-
Dynamic evaluation of adrenal hypofunction.J Endocrinol Invest. 2003;26(7 Suppl):74-82. J Endocrinol Invest. 2003. PMID: 14604069 Review.
-
The assessment of the hypothalamo-pituitary-adrenal axis in pituitary disease: are there short cuts?J Endocrinol Invest. 2003;26(7 Suppl):25-30. J Endocrinol Invest. 2003. PMID: 14604063 Review.
Cited by
-
Estimation of maximal cortisol secretion rate in healthy humans.J Clin Endocrinol Metab. 2012 Apr;97(4):1285-93. doi: 10.1210/jc.2011-2227. Epub 2012 Feb 15. J Clin Endocrinol Metab. 2012. PMID: 22337905 Free PMC article. Clinical Trial.
-
Repetitive graded ACTH stimulation test for adrenal insufficiency.J Endocrinol Invest. 2000 Mar;23(3):163-9. doi: 10.1007/BF03343700. J Endocrinol Invest. 2000. PMID: 10803473 Clinical Trial.
-
Cortisol Secretion in Obesity Revisited: Lower Basal Serum and Salivary Cortisol with Diminished Cortisol Response to the Low Dose ACTH Challenge.Obes Facts. 2025;18(2):178-186. doi: 10.1159/000543449. Epub 2025 Jan 8. Obes Facts. 2025. PMID: 39778537 Free PMC article.
-
Serum Cortisol Level in Indian Patients with Severe Sepsis/Septic Shock.J Emerg Trauma Shock. 2017 Oct-Dec;10(4):194-198. doi: 10.4103/JETS.JETS_123_16. J Emerg Trauma Shock. 2017. PMID: 29097858 Free PMC article.
-
Assessment of hypothalamic-pituitary-adrenal axis impairment and effects of hydrocortisone treatment in adults with Prader-Willi syndrome.Front Endocrinol (Lausanne). 2025 Jun 4;16:1517334. doi: 10.3389/fendo.2025.1517334. eCollection 2025. Front Endocrinol (Lausanne). 2025. PMID: 40535342 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical