High-resolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties
- PMID: 9600777
- DOI: 10.1016/s8756-3282(98)00030-1
High-resolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties
Abstract
The purpose of this study was to use high-resolution magnetic resonance (MR) imaging combined with image analysis to investigate the three-dimensional (3D) trabecular structure, anisotropy, and connectivity of human vertebral, femoral, and calcaneal specimens. The goal was to determine whether: (a) MR-derived measures depict known skeletal-site-specific differences in architecture and orientation of trabeculae; (b) 3D architectural parameters combined with bone mineral density (BMD) improve the prediction of the elastic modulus using a fabric tensor formulation; (c) MR-derived 3D architectural parameters combined with BMD improve the prediction of strength using a multiple regression model, and whether these results corresponded to the results obtained using higher resolution depictions of trabecular architecture. A total of 94 specimens (12 x 12 x 12 mm cubes) consisting of trabecular bone only were obtained, of which there were 7 from the calcaneus, 15 from distal femur, 47 from the proximal femur, and 25 from the vertebral bodies. MR images were obtained using a 1.5 Tesla MR scanner at a spatial resolution of 117 x 117 x 300 microm. Additionally, BMD was determined using quantitative computed tomography (QCT), and the specimens were nondestructively tested and the elastic modulus (YM) was measured along three orthogonal axes corresponding to the anatomic superior-inferior (axial), medial-lateral (sagittal), and anterior-posterior (coronal) directions. A subset of the specimens (n=67) was then destructively tested in the superior-inferior (axial) direction to measure the ultimate compressive strength. The MR images were segmented into bone and marrow phases and then analyzed in 3D. Ellipsoids were fitted to the mean intercept lengths, using single value decomposition and the primary orientation of the trabeculae and used to calculate the anisotropy of trabecular architecture. Stereological measures were derived using a previously developed model and measures such as mean trabecular width, spacing, and number were derived. Because the spatial resolution of MR images is comparable to trabecular bone dimensions, these measures may be subject to partial volume effects and were thus treated as apparent measures, such as BV/TV, Tb.Sp, Tb.N, and Tb.Th rather than absolute measures, as would be derived from histomorphometry. In addition, in a subset of specimens, the Euler number per unit volume was determined to characterize the connectivity of the trabecular network. There were significant differences in the BMD, trabecular architectural measures, elastic modulus, and strength at the different skeletal sites. The primary orientation axes for most of the specimens was the anatomic superior-inferior (axial) direction. Using the fabric tensor formulation, in addition to BMD, improved the prediction of YM (SI), while including some of the architectural parameters significantly improved the prediction of strength. In comparing MR-derived 3D measures with those obtained from 20 microm optical images (n=18; 9 vertebrae, 9 femur specimens), good correlations were found for the apparent Tb.Sp and Tb.N, moderate correlation was seen for the apparent BV/TV, and poor correlation was found for the apparent Tb.Th. Using these higher resolution images, the fabric tensor formulation for predicting the elastic modulus also showed improved correlation between the measured and calculated modulus in the axial (SI) direction. In summary, high-resolution MR images may be used to assess 3D architecture of trabecular bone, and the inclusion of some of the 3D architectural measures provides an improved assessment of biomechanical properties. Further studies are clearly warranted to establish the role of architecture in predicting overall bone quality, and the role of trabecular architecture measures in clinical practice. (ABSTRACT TRUNCATED)
Similar articles
-
Evaluation of changes in trabecular bone architecture and mechanical properties of minipig vertebrae by three-dimensional magnetic resonance microimaging and finite element modeling.J Bone Miner Res. 2000 Sep;15(9):1786-97. doi: 10.1359/jbmr.2000.15.9.1786. J Bone Miner Res. 2000. PMID: 10976998
-
In vivo assessment of architecture and micro-finite element analysis derived indices of mechanical properties of trabecular bone in the radius.Osteoporos Int. 2002 Jan;13(1):6-17. doi: 10.1007/s198-002-8332-0. Osteoporos Int. 2002. PMID: 11878456
-
Fractal analysis of radiographs: assessment of trabecular bone structure and prediction of elastic modulus and strength.Med Phys. 1999 Jul;26(7):1330-40. doi: 10.1118/1.598628. Med Phys. 1999. PMID: 10435535
-
A review of magnetic resonance (MR) imaging of trabecular bone micro-architecture: contribution to the prediction of biomechanical properties and fracture prevalence.Technol Health Care. 1998 Dec;6(5-6):321-7. Technol Health Care. 1998. PMID: 10100935 Review.
-
Assessment of trabecular structure using high resolution magnetic resonance imaging.Stud Health Technol Inform. 1997;40:81-96. Stud Health Technol Inform. 1997. PMID: 10168884 Review.
Cited by
-
Osteoporosis imaging: state of the art and advanced imaging.Radiology. 2012 Apr;263(1):3-17. doi: 10.1148/radiol.2633201203. Radiology. 2012. PMID: 22438439 Free PMC article. Review.
-
Mechanical properties of femoral trabecular bone in dogs.Biomed Eng Online. 2005 Mar 17;4:17. doi: 10.1186/1475-925X-4-17. Biomed Eng Online. 2005. PMID: 15774014 Free PMC article.
-
Trabecular bone microarchitecture in female collegiate gymnasts.Osteoporos Int. 2008 Jul;19(7):1011-8. doi: 10.1007/s00198-007-0522-x. Epub 2007 Dec 12. Osteoporos Int. 2008. PMID: 18074110
-
Changes in the fractal dimension of peri-implant trabecular bone after loading: a retrospective study.J Periodontal Implant Sci. 2013 Oct;43(5):209-14. doi: 10.5051/jpis.2013.43.5.209. Epub 2013 Oct 29. J Periodontal Implant Sci. 2013. PMID: 24236242 Free PMC article.
-
The effect of bone ingrowth depth on the tensile and shear strength of the implant-bone e-beam produced interface.J Mater Sci Mater Med. 2011 Oct;22(10):2339-46. doi: 10.1007/s10856-011-4419-z. Epub 2011 Aug 21. J Mater Sci Mater Med. 2011. PMID: 21858722
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources