Peripheral bone densitometry: an old friend revisited
- PMID: 9601128
- PMCID: PMC2194331
Peripheral bone densitometry: an old friend revisited
Abstract
The earliest assessments of bone "mass" involved metacarpal morphometry that provided insight into age-related changes, the effects of low habitual dietary calcium intake, and the effects of estrogen deficiency and replacement. Single photon absorptiometry (SPA) made quantitative mass measurement possible but this was intellectually unsatisfactory since osteoporotic fractures are more of a concern at the spine and hip than at the wrist. Necessity forced the development of axial bone mass measurement (dual photon absorptiometry--DPA, dual energy xray absorptiometry--DXA, quantitative computed tomography--QCT). Hip measurements provide a better prediction of hip fracture risk than measurements at any other skeletal site. For every standard deviation decrement of bone mass at the hip, relative risk of fracture is 3.0. At non-hip sites the relative risk is only 2.0 for each standard deviation decrement in bone mass. However measurement at non-hip sites provide a fracture risk prediction that is at least the equal of blood pressure measurement for predicting risk of CVA, and substantially better than the risk assessment of acute MI afforded by cholesterol measurement. An important caveat of the superiority of hip measurement is that the data are derived from short-term studies in older women (> 70 years). The relative risk data from phalangeal, forearm, and heel measurements have all been obtained from longer-term studies in younger women. From a community health perspective, bone density measurements, no matter how accurate, precise, and meaningful, have limited value if access to the technology is limited. Peripheral measurements can be obtained on existing radiographic equipment (phalanges), or small, portable, inexpensive dedicated equipment (forearm, heel). This technology is more likely to make it to the office of the primary care physician than the larger, more expensive, dedicated equipment needed for hip measurements. The peripheral measurement technology is also suitable for high traffic areas, just as blood pressure and cholesterol measurements are widely available. This presentation reviewed the scientific validity of peripheral bone mass measurement and explored the potential for making this technology available at non-traditional facilities such as pharmacies, shopping malls, health clubs, etc.
Similar articles
-
Osteoporosis case finding in the general practice: phalangeal radiographic absorptiometry with and without risk factors for osteoporosis to select postmenopausal women eligible for lumbar spine and hip densitometry.Osteoporos Int. 2005 Nov;16(11):1353-62. doi: 10.1007/s00198-005-1846-z. Epub 2005 Feb 12. Osteoporos Int. 2005. PMID: 15711776
-
Bone mass measurement: how, where, when and why?Int J Fertil Menopausal Stud. 1993;38 Suppl 2:70-6. Int J Fertil Menopausal Stud. 1993. PMID: 8252108 Review.
-
The discriminative ability of peripheral and axial bone measurements to identify proximal femoral, vertebral, distal forearm and proximal humeral fractures: a case control study.Osteoporos Int. 2005 Dec;16(12):1794-802. doi: 10.1007/s00198-005-1931-3. Epub 2005 Jun 10. Osteoporos Int. 2005. PMID: 15947861
-
Bone mass measurement in identification of women at risk for osteoporosis.Int J Fertil Womens Med. 1999 Nov-Dec;44(6):269-78. Int J Fertil Womens Med. 1999. PMID: 10617248 Review.
-
Comparative assessment of bone mineral measurements using dual X-ray absorptiometry and peripheral quantitative computed tomography.Osteoporos Int. 1998;8(5):460-7. doi: 10.1007/s001980050092. Osteoporos Int. 1998. PMID: 9850355 Clinical Trial.
Cited by
-
Differences in precision in bone mineral density measured by SXA and DXA: the NOREPOS study.Eur J Epidemiol. 2008;23(9):615-24. doi: 10.1007/s10654-008-9271-1. Epub 2008 Jul 2. Eur J Epidemiol. 2008. PMID: 18594994
References
MeSH terms
LinkOut - more resources
Full Text Sources
Medical