Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw
- PMID: 9619458
- DOI: 10.1097/00005131-199805000-00005
Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw
Abstract
Objective: To compare the results after operative treatment of unstable per- and subtrochanteric fractures with the Gamma nail, compression hip screw (CHS), or dynamic hip screw with a laterally mounted trochanteric stabilizing plate (DHS/TSP).
Design: Prospective.
Patients: One hundred seventy patients with unstable trochanteric femoral fractures surviving six months after operation. Eighty-five patients were randomized to treatment with the Gamma nail (n = 50, Gamma group) or the compression hip screw (n = 35, CHS group) and compared with a consecutive series of eighty-five patients operated with the dynamic hip screw with a laterally mounted trochanteric stabilizing plate (DHS/TSP group)
Main outcome measurements: Radiographs were analyzed for fracture classification, evaluation of fracture reduction, implant positioning, later fracture dislocation, and other complications. Pre- and postoperative functional status of the patients were recorded, with a minimum of six months follow-up.
Results: Eighteen percent of the patients in the Gamma group, 34 percent in the CHS group, and 9 percent in the DHS/TSP group suffered significant secondary fracture dislocation during the six months follow-up, leading to a varus malunion, lag screw cutout, or excessive lag screw sliding with medialization of the distal fracture fragment. Two patients (4.0 percent) in the Gamma group suffered an implant-related femoral fracture below the nail, and one had a deep infection. The reoperation rates were 8.0 percent in the Gamma group, 2.9 percent in the CHS group, and 5.9 percent in the DHS/TSP group. All but one fracture in the Gamma and CHS groups and two fractures in the DHS/TSP group healed within six months. Approximately three-fourths of the patients had returned to their preoperative walking ability after six months, with a trend toward better functional outcome in the DHS/TSP group. Use of a TSP reduced the secondary lag screw sliding as compared with the conventional CHS, without affecting fracture healing.
Conclusion: The TSP may be an aid in the treatment of these difficult fractures because the problem with femoral shaft fractures using the Gamma nail is avoided and the medialization of the distal fracture fragment frequently associated with the CHS is prevented.
Similar articles
-
Clinical results using the trochanter stabilizing plate (TSP): the modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures.J Orthop Trauma. 1998 Aug;12(6):392-9. doi: 10.1097/00005131-199808000-00005. J Orthop Trauma. 1998. PMID: 9715446
-
Outcomes of dynamic hip screw augmented with trochanteric wiring for treatment of unstable type A2 intertrochanteric femur fractures.Injury. 2017 Aug;48 Suppl 2:S72-S77. doi: 10.1016/S0020-1383(17)30498-9. Injury. 2017. PMID: 28802425
-
Comparison of compression hip screw and gamma nail for treatment of peritrochanteric fractures.J South Orthop Assoc. 1997 Fall;6(3):173-9. J South Orthop Assoc. 1997. PMID: 9322196
-
[Therapeutic possibilities in trochanteric fractures. Safe--fast--stable].Orthopade. 2000 Apr;29(4):294-301. doi: 10.1007/s001320050450. Orthopade. 2000. PMID: 10851690 Review. German.
-
Alternative techniques in trochanteric hip fracture surgery. Clinical and biomechanical studies on the Medoff sliding plate and the Twin hook.Acta Orthop Scand Suppl. 2000 Oct;295:1-31. Acta Orthop Scand Suppl. 2000. PMID: 11116961 Review.
Cited by
-
A biomechanical evaluation of proximal femoral nail antirotation with respect to helical blade position in femoral head: A cadaveric study.Indian J Orthop. 2012 Nov;46(6):627-32. doi: 10.4103/0019-5413.104186. Indian J Orthop. 2012. PMID: 23325963 Free PMC article.
-
[The rotationally stable screw-anchor with trochanteric stabilizing plate (RoSA/TSP) : First results in unstable trochanteric femur fractures].Unfallchirurg. 2017 Dec;120(12):1054-1064. doi: 10.1007/s00113-016-0265-2. Unfallchirurg. 2017. PMID: 27770169 German.
-
Treatment of trochanteric fractures with the gamma3 nail - methodology and early results of a prospective consecutive monitored clinical case series.Open Orthop J. 2014 Dec 29;8:466-73. doi: 10.2174/1874325001408010466. eCollection 2014. Open Orthop J. 2014. PMID: 25621082 Free PMC article.
-
Influence of osteoporosis on fracture fixation--a systematic literature review.Osteoporos Int. 2008 Jun;19(6):761-72. doi: 10.1007/s00198-007-0515-9. Osteoporos Int. 2008. PMID: 18066697
-
Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients.Int Orthop. 2010 Dec;34(8):1273-6. doi: 10.1007/s00264-009-0866-2. Epub 2009 Sep 26. Int Orthop. 2010. PMID: 19784649 Free PMC article. Clinical Trial.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous