Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1998 May;23(3):446-53.
doi: 10.1016/S0363-5023(05)80462-9.

High-speed, three-dimensional kinematic analysis of the normal wrist

Affiliations

High-speed, three-dimensional kinematic analysis of the normal wrist

R M Patterson et al. J Hand Surg Am. 1998 May.

Abstract

Carpal kinematics during a wrist flexion/extension motion using high-speed videodata acquisition was investigated. A cadaver forearm was stabilized, allowing unconstrained excursion of the wrist for passive range of motion (ROM). The extensor and flexor pairs of the wrist were looped together and a 1-lb weight was attached to each pair, simulating synergistic muscle tension. Capitate/radius and third metacarpal/radius angles were calculated to determine which measurement would be best for determining global wrist angle. The average difference in capitate/radius and third metacarpal/radius angles at each respective flexion/extension wrist angle for all wrists was 1.1 degrees +/- 1.6 degrees (the maximum difference was 4 degrees). Hence, the capitate-third metacarpal joint can be considered rigid. Capitate/lunate motion as described by capitate-radius Euler angles ranged from -16.9 to 23.5 with total capitate/lunate motion of 40.5 (35%) in the 114 degrees total global wrist ROM measured. Radius/lunate motion as described by lunate-radius angle ranged from -8.2 to 48.4 with total radius/lunate motion of 56.5 (49%) in the 114 degrees total global wrist ROM measured. During global wrist motion, the radiolunate joint contributes more motion in flexion than the capitolunate joint and the capitolunate joint contributes more motion in extension than the radiolunate joint. The instantaneous screw axes (ISAs) were calculated for each third metacarpal position with respect to the radius. The average distance difference between ISAs for the 4 wrists tested was -1.23 +/- 14.97 pixels. The maximum distance was 56.51 pixels and the minimum was -24.09 pixels. This new combination of motion analysis and 3-dimensional reconstructions of computed tomography images affords a high-speed, dynamic analysis of kinematics. It shows that during wrist flexion/extension, normal carpal kinematics does not have an ISA fixed in or limited to the capitate. In addition, the ISA data provide evidence that translational motion is a real and measurable component of normal carpal motion. These findings alter the understanding of carpal kinematics obtained from the results of previous studies which suggested that the center of rotation was fixed in the capitate.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources