Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1998 May-Jun;21(3):230-3.
doi: 10.1007/s002709900250.

Peripheral insertion of a central venous access device under fluoroscopic guidance using a peripherally accessed system (PAS) port in the forearm

Affiliations

Peripheral insertion of a central venous access device under fluoroscopic guidance using a peripherally accessed system (PAS) port in the forearm

Y Hata et al. Cardiovasc Intervent Radiol. 1998 May-Jun.

Abstract

Purpose: We describe the technique, efficacy, and complications of fluoroscopy-guided implantation of a central venous access device using a peripherally accessed system (PAS) port via the forearm.

Methods: Beginning in July 1994, 105 central venous access devices were implanted in 104 patients for the long-term infusion of antibiotics or antineoplasmic agents, blood products, or parenteral nutrition. The devices was inserted under fluoroscopic guidance with real-time venography from a peripheral route.

Results: All ports were successfully implanted. There were no procedure-related complications. No thrombosis or local infection was observed; however, in six patients catheter-related phlebitis occurred.

Conclusion: Fluoroscopy-guided implantation of a central venous access device using a PAS port via the forearm is safe and efficacious, and injection of contrast medium through a peripheral IV catheter before introduction of the catheter helps to avoid catheter-related phlebitis.

PubMed Disclaimer