The value of respiratory triggered T2-weighted turbo spin-echo imaging of the liver using a phased array coil
- PMID: 9626882
- DOI: 10.1002/jmri.1880080321
The value of respiratory triggered T2-weighted turbo spin-echo imaging of the liver using a phased array coil
Abstract
The purpose of this study was to evaluate the value of the respiratory triggered turbo spin-echo (TSE) technique for T2-weighted MRI of liver lesions. Fifty-nine patients (32 men, 27 women; mean age, 63.3 years) with focal hepatic lesions were prospectively studied with MRI at 1.5 T with use of a body phased array coil. In the first 15 patients, breath-hold TSE, respiratory triggered TSE, and conventional nonrespiratory triggered TSE T2-weighted imaging were compared. Because nonrespiratory triggered TSE imaging was significantly inferior (P < .01) to breath-hold or respiratory triggered images, breath-hold and respiratory triggered TSE T2-weighted images were compared in the remaining 44 patients. Images were analyzed quantitatively by measuring the liver signal-to-noise ratio and the lesion-liver and spleen-liver contrast-to-noise ratios and qualitatively by evaluating the lesion conspicuity, liver parenchymal homogeneity, and sharpness of intrahepatic vessels. The imaging time was 26 seconds for breath-hold TSE imaging, 49 to 219 seconds (mean, 149 seconds) for the respiratory triggered TSE imaging, and 79 to 379 seconds (mean, 239 seconds) for the nonrespiratory triggered TSE imaging. Quantitatively, the signal-to-noise ratio of the liver for breath-hold imaging was comparable to that for respiratory triggered imaging. The lesion-liver and liver-spleen contrast-to-noise ratios for the respiratory triggered images were greater by 37% and 39%, respectively, than for the breath-hold T2-weighted TSE images. Qualitatively, the respiratory triggered images showed lower frequency of image artifact, better lesion conspicuity, and greatly superior depiction of intrahepatic structures compared with the breath-hold T2-weighted TSE images. The respiratory triggered T2-weighted TSE technique provides better quality liver images than the breath-hold TSE technique or nonrespiratory triggered technique within a reasonable acquisition time.
Similar articles
-
Phased array breath-hold versus non-breath-hold MR imaging of focal liver lesions: a prospective comparative study.J Magn Reson Imaging. 1997 Mar-Apr;7(2):292-7. doi: 10.1002/jmri.1880070206. J Magn Reson Imaging. 1997. PMID: 9090580 Clinical Trial.
-
Hepatic T2-weighted MRI: a prospective comparison of sequences, including breath-hold, half-Fourier turbo spin echo (HASTE).J Magn Reson Imaging. 1998 May-Jun;8(3):642-9. doi: 10.1002/jmri.1880080319. J Magn Reson Imaging. 1998. PMID: 9626880
-
T2-weighted MR imaging for hepatic hemangiomas: comparison of breath-hold and non-breath-hold turbo spin-echo pulse sequences with phased-array multicoil.Abdom Imaging. 1998 Jul-Aug;23(4):422-6. doi: 10.1007/s002619900372. Abdom Imaging. 1998. PMID: 9663280
-
[PSIF/CE-FAST (fast gradient echo) and TSE (turbo spin echo)].Nihon Rinsho. 1998 Nov;56(11):2773-7. Nihon Rinsho. 1998. PMID: 9847597 Review. Japanese.
-
Parallel imaging of the abdomen.Top Magn Reson Imaging. 2004 Jun;15(3):197-206. doi: 10.1097/01.rmr.0000136557.27727.79. Top Magn Reson Imaging. 2004. PMID: 15480001 Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical