. 1998 Jun;39(6):938-44.

First-pass radionuclide angiography using iodine-123 myocardial tracers and a multicrystal gamma camera

Affiliations
  • PMID: 9627322
Free article

First-pass radionuclide angiography using iodine-123 myocardial tracers and a multicrystal gamma camera

E Tadamura et al. J Nucl Med. 1998 Jun.
Free article

Abstract

The purpose of this study was to validate the accuracy of the assessment of ventricular function by first-pass radionuclide angiography (FPRNA) with 123I myocardial tracers and a multicrystal gamma camera.

Methods: Left ventricular ejection fraction (LVEF) and right ventricular ejection fraction were measured in 69 patients by FPRNA using 123I myocardial tracers (126 +/- 7 MBq) and 99mTc tracers (541 +/- 141 MBq) on a multicrystal gamma camera with a high-sensitivity collimator. For 44 patients, ejection fraction values measured by 123I-FPRNA were compared to those estimated by equilibrium radionuclide angiography (ERNA). Visual wall-motion analysis was also performed to judge clinical acceptability of 123I-FPRNA images for identification of wall-motion abnormality.

Results: Mean LVEFs (%) estimated by 123I-FPRNA and by 99mTc-FPRNA were 49.6 +/- 13.6 and 49.1 +/- 14.1, respectively (nonsignificant p value). An excellent correlation was found between LVEFs estimated by 123I-FPRNA and 99mTc-FPRNA (r = 0.96, s.e.e. = 1.9%). Values of LVEF measured by 123I-FPRNA also demonstrated excellent correlation with those measured by ERNA (r = 0.95, s.e.e. = 2.2%). A good correlation was also noted between right ventricular ejection fractions measured by 123I-FPRNA and 99mTc-FPRNA (r = 0.72, s.e.e. = 4.0%). The Spearman rank correlation coefficient between 123I-FPRNA and ERNA wall-motion scores was 0.87 (n = 135, p < 0.001).

Conclusion: Resting ventricular function can be reliably measured with 123I-FPRNA in combination with a multicrystal gamma camera. This indicates that the assessment of ventricular function is feasible in conjunction with 123I myocardial imaging without an increase in cost or radiation dose to patients.