Performance of a safe proximal anastomosis in aortic dissection
- PMID: 9647115
- DOI: 10.1016/s0003-4975(98)00214-8
Performance of a safe proximal anastomosis in aortic dissection
Abstract
Because of the increased fragility of a freshly dissected aorta, the anastomosis between the aortic root and a tubular prosthesis is not forgiving of technical imperfections and may lead to troublesome bleeding. Providing an appropriate everting surface of contact and a homogeneous distribution of tension between the graft and aorta, as described here, should help obtain a hemostatic suture line.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources