Abstract
A bewildering array of HMEs are available, suited to many different tidal volume and other clinical requirements. Choosing among the different devices depends on many attributes. Grouping different HMEs together to describe their performance may be inappropriate. Independent tests on HMEs provide information to help when choosing among different devices, but care should be exercised to prevent inappropriate comparisons being made between results from studies using different test procedures and protocols. The use of filters in anesthesia is recommended in some countries. Some HMEs have a high moisture-conserving performance, but the use of HMEs may be inappropriate for some patient groups, and other humidifying devices may be more suitable.
Similar articles
-
Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: a prospective clinical, hygrometric, and bacteriologic study.Crit Care Med. 2003 Mar;31(3):823-9. doi: 10.1097/01.CCM.0000055382.87129.DD. Crit Care Med. 2003. PMID: 12626991 Clinical Trial.
-
Heat and moisture exchangers in mechanically ventilated intensive care unit patients: a plea for an independent assessment of their performance.Crit Care Med. 2003 Mar;31(3):699-704. doi: 10.1097/01.CCM.0000050443.45863.F5. Crit Care Med. 2003. PMID: 12626972 Clinical Trial.
-
In vitro and in vivo evaluation of a new active heat moisture exchanger.Crit Care. 2004 Oct;8(5):R281-8. doi: 10.1186/cc2904. Epub 2004 Jun 28. Crit Care. 2004. PMID: 15469569 Free PMC article.
-
Heated humidifiers. Structure and function.Respir Care Clin N Am. 1998 Jun;4(2):243-59. Respir Care Clin N Am. 1998. PMID: 9648185 Review.
-
Humidification in intensive care.S Afr J Surg. 1994 Mar;32(1):23-30. S Afr J Surg. 1994. PMID: 11218439 Review.
Cited by
-
Humidification and heating of inhaled gas in patients with artificial airway. A narrative review.Rev Bras Ter Intensiva. 2018 Mar;30(1):86-97. doi: 10.5935/0103-507x.20180015. Rev Bras Ter Intensiva. 2018. PMID: 29742220 Free PMC article. Review.
-
Microbiological safety and cost-effectiveness of weekly breathing circuit changes in combination with heat moisture exchange filters: a prospective longitudinal clinical survey.GMS Krankenhhyg Interdiszip. 2011;6(1):Doc15. doi: 10.3205/dgkh000172. Epub 2011 Dec 15. GMS Krankenhhyg Interdiszip. 2011. PMID: 22242096 Free PMC article.