Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1998 Apr;58(4):319-25.
doi: 10.1016/s0952-3278(98)90042-4.

Radioimmunoassay of 8-iso-prostaglandin F2alpha: an index for oxidative injury via free radical catalysed lipid peroxidation

Affiliations

Radioimmunoassay of 8-iso-prostaglandin F2alpha: an index for oxidative injury via free radical catalysed lipid peroxidation

S Basu. Prostaglandins Leukot Essent Fatty Acids. 1998 Apr.

Abstract

8-iso-prostaglandin F2alpha (8-iso-PGF2alpha), a major F2-isoprostane, is biosynthesized in vivo through nonenzymatic free radical-catalysed peroxidation of arachidonic acid. The levels of F2-isoprostanes both free in the circulation and esterified to the tissue phospholipids increase intensely in animal models of oxidant injury. This study presents the development and validation of a radioimmunoassay of 8-iso-PGF2alpha for the measurement of this substance in the body fluids. Furthermore, its application in normal human volunteers, a pharmacokinetic study performed in rabbits with 8-iso-PGF2alpha, and hepatic lipid peroxidation in rats is reported. An antibody was raised in rabbits by immunization with 8-iso-PGF2alpha coupled to BSA at the carboxylic acid by 1,1'-Carbonyldiimmidazole method. The cross-reactivity of the antibody with 8-iso-15-keto-13,14-dihydro-PGF2alpha, 8-iso-PGF2beta, PGF2alpha, 15-keto-PGF2alpha, 15-keto-13,14-dihydro-PGF2alpha,TXB2, 11beta-PGF2alpha, 9beta-PGF2alpha and 8-iso-PGF3alpha was 1.7, 9.8, 1.1, 0.01, 0.01, 0.1, 0.03, 1.8 and 0.6%, respectively. The intraassay precision was 14.5% (CV) at the level of 64 pg/0.1 ml and 12.2% with 512 pg/0.1 ml in the human plasma. Similarly, intra-assay accuracy was 95.6% and 101% for the low and the high standard, respectively. The detection limit was about 23 pmol/l. The appearance and disappearance of 8-iso-PGF2alpha in the blood and urine following intravenous administration of 8-iso-PGF2alpha in the rabbit was rapid. Free 8-iso-PGF2alpha levels in plasma and urine from normal human volunteers are evaluated and found to correlate with the obtained values by gas chromatography-mass spectrometry methods from other studies. The levels of free 8-iso-PGF2alpha in the plasma and urine increased 7- and 102-fold, respectively, after CCl4 administration to rats. Thus, this 8-iso PGF2alpha radioimmunoassay method is relevant to apply in the oxidative injury studies as an index of in vivo lipid peroxidation through free radical catalysis mechanism.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources