Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler
- PMID: 9655710
- DOI: 10.1164/ajrccm.158.1.9707031
Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler
Abstract
Measurement of cardiac output using thermodilution technique in mechanically ventilated patients is associated with significant morbidity. The goal of the present study was to assess the validity of cardiac output measurement using transesophageal Doppler in critically ill patients. Forty-six patients from three different intensive care units underwent 136 paired cardiac output measurements using thermodilution (COTH) and transesophageal Doppler (COTED). In addition, simultaneous suprasternal Doppler and indirect calorimetry (Fick principle) were used to measure cardiac output in 26 patients from one center. A good correlation was found between COTH and COTED (r = 0.95), with a small systematic underestimation (bias = 0.24 L/min) using transesophageal Doppler. The limits of agreement between COTH and COTED were +2 L/min and -1.5 L/min. Variations in cardiac output between two consecutive measures using either transesophageal Doppler or thermodilution techniques were similar in direction and magnitude (bias = 0 L/min; limits of agreement = +/-1.7 L/min). Suprasternal Doppler and indirect calorimetry yielded similar correlations and agreements in the subset of patients in whom they were used. These results confirm that transesophageal Doppler can provide a noninvasive, clinically useful estimate of cardiac output and detect hemodynamic changes in mechanically ventilated, critically ill patients.
Similar articles
-
[Monitoring cardiac output: esophageal doppler vs thermodilution].Minerva Anestesiol. 1998 Jul-Aug;64(7-8):351-6. Minerva Anestesiol. 1998. PMID: 9796245 Clinical Trial. Italian.
-
Measurement of cardiac output by transesophageal echocardiography in mechanically ventilated patients. Comparison with thermodilution.Intensive Care Med. 1997 Jul;23(7):753-9. doi: 10.1007/s001340050405. Intensive Care Med. 1997. PMID: 9290989 Clinical Trial.
-
Transoesophageal echocardiography accurately detects cardiac output variation: a prospective comparison with thermodilution in cardiac surgery.Eur J Anaesthesiol. 2008 Feb;25(2):135-43. doi: 10.1017/S0265021507001354. Epub 2007 Aug 2. Eur J Anaesthesiol. 2008. PMID: 17672920
-
The validity of trans-esophageal Doppler ultrasonography as a measure of cardiac output in critically ill adults.Intensive Care Med. 2004 Nov;30(11):2060-6. doi: 10.1007/s00134-004-2430-2. Epub 2004 Sep 11. Intensive Care Med. 2004. PMID: 15368037 Review.
-
Continuous measurement of cardiac output by the Fick principle in infants and children: comparison with the thermodilution method.Intensive Care Med. 1996 May;22(5):467-71. doi: 10.1007/BF01712169. Intensive Care Med. 1996. PMID: 8796404 Review.
Cited by
-
Identification of volume parameters monitored with a noninvasive ultrasonic cardiac output monitor for predicting fluid responsiveness in children after congenital heart disease surgery.Medicine (Baltimore). 2018 Sep;97(39):e12289. doi: 10.1097/MD.0000000000012289. Medicine (Baltimore). 2018. PMID: 30278500 Free PMC article. Clinical Trial.
-
[Noninvasive determination of cardiac output in ventilated patients . Clinical evaluation of a simplified quick method].Anaesthesist. 2003 Sep;52(9):778-86. doi: 10.1007/s00101-003-0547-2. Anaesthesist. 2003. PMID: 14504803 Clinical Trial. German.
-
Use of transesophageal Doppler as a sole cardiac output monitor for reperfusion hemodynamic changes during living donor liver transplantation: An observational study.Saudi J Anaesth. 2011 Jul;5(3):264-9. doi: 10.4103/1658-354X.84099. Saudi J Anaesth. 2011. PMID: 21957404 Free PMC article.
-
Minimally invasive monitoring of cardiac output in the cardiac surgery intensive care unit.Curr Heart Fail Rep. 2010 Sep;7(3):116-24. doi: 10.1007/s11897-010-0019-3. Curr Heart Fail Rep. 2010. PMID: 20623210 Review.
-
Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery.Intensive Care Med. 2012 Jun;38(6):1032-9. doi: 10.1007/s00134-012-2530-3. Epub 2012 Mar 30. Intensive Care Med. 2012. PMID: 22460851
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources