Spiral CT scanning in the detection and evaluation of aneurysms of the Circle of Willis
- PMID: 9657493
- DOI: 10.1016/s0090-3019(98)00015-9
Spiral CT scanning in the detection and evaluation of aneurysms of the Circle of Willis
Abstract
Purpose: To assess the utility of spiral computed tomography (CT) with three-dimensional reconstruction in defining aneurysms of the Circle of Willis.
Methods: Eighty-one patients with angiographic or surgical correlation were studied between 1993 and 1995, with surface rendered reconstructions of the arteries of the Circle of Willis.
Results: Spiral CT was useful in six clinical situations: further assessment in cases with CT suspicion of an aneurysm, follow-up of known untreated aneurysms or aneurysm remnants, subarachnoid hemorrhage (SAH) with negative angiography, a past or family history of aneurysms, and improved definition of aneurysm anatomy. Ten of fifteen patients with previous surgery had no significant artifacts on the spiral study. In 66 other patients studied in search of aneurysms, the sensitivity of detection was 95% and specificity 74%. Seventeen of nineteen aneurysms 3 mm or less in size and 38 of 39 larger were detected by spiral CT. Four of thirteen patients with SAH and previous negative angiography had aneurysms identified, which were confirmed at surgery.
Conclusions: There is great promise in the use of spiral CT in demonstrating aneurysms of the Circle of Willis, including very small ones. Careful detailing of scan protocols and meticulous examination of multiplanar images are needed for maximum accuracy.
Similar articles
-
Intracranial aneurysms: evaluation in 200 patients with spiral CT angiography.Eur Radiol. 2001;11(1):123-30. doi: 10.1007/s003300000523. Eur Radiol. 2001. PMID: 11194903
-
Evaluation of the circle of Willis with three-dimensional CT angiography in patients with suspected intracranial aneurysms.AJNR Am J Neuroradiol. 1995 Sep;16(8):1571-8; discussion 1579-80. AJNR Am J Neuroradiol. 1995. PMID: 7502958 Free PMC article.
-
Detection of circle of Willis aneurysms in patients with acute subarachnoid hemorrhage: a comparison of CT angiography and digital subtraction angiography.AJR Am J Roentgenol. 1995 Aug;165(2):425-30. doi: 10.2214/ajr.165.2.7618571. AJR Am J Roentgenol. 1995. PMID: 7618571
-
[CT-angiography for diagnostic assessment of intracranial vascular aneurysms].Wien Med Wochenschr. 1997;147(7-8):163-71. Wien Med Wochenschr. 1997. PMID: 9297365 Review. German.
-
CT angiography of the intracranial circulation.Neuroimaging Clin N Am. 1998 Aug;8(3):577-92. Neuroimaging Clin N Am. 1998. PMID: 9673314 Review.
Cited by
-
Cerebral aneurysm exclusion by CT angiography based on subarachnoid hemorrhage pattern: a retrospective study.BMC Neurol. 2011 Jan 21;11:8. doi: 10.1186/1471-2377-11-8. BMC Neurol. 2011. PMID: 21255395 Free PMC article.
-
Anatomy and frequency of large pontomesencephalic veins on 3D CT angiograms of the circle of Willis.AJNR Am J Neuroradiol. 2003 Sep;24(8):1598-601. AJNR Am J Neuroradiol. 2003. PMID: 13679277 Free PMC article.
-
Subtraction helical CT angiography of intra- and extracranial vessels: technical considerations and preliminary experience.AJNR Am J Neuroradiol. 2003 Mar;24(3):451-5. AJNR Am J Neuroradiol. 2003. PMID: 12637296 Free PMC article.
-
Detection of intracranial aneurysms with multislice CT: comparison with conventional angiography.Neuroradiology. 2004 Jun;46(6):427-34. doi: 10.1007/s00234-003-1155-1. Epub 2004 Apr 23. Neuroradiology. 2004. PMID: 15105978
-
Early Experience Studying Cerebral Aneurysms with Rotational and Threedimensional Angiography and Review of CT and MR Angiography Literature.Interv Neuroradiol. 2002 Dec 22;8(4):377-91. doi: 10.1177/159101990200800407. Epub 2004 Oct 20. Interv Neuroradiol. 2002. PMID: 20594499 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous