The emergence of flow cytometry for sensitive, real-time measurements of molecular interactions
- PMID: 9661195
- DOI: 10.1038/nbt0798-633
The emergence of flow cytometry for sensitive, real-time measurements of molecular interactions
Abstract
The analysis of macromolecular interactions is an essential element of biomedical research. Flow cytometry is uniquely capable of making sensitive and quantitative measurements of molecular interactions. These measurements can be made in real time with subsecond kinetic resolution using purified biomolecules or living cells. Combined with automated sample handling, these features make flow cytometry a versatile and robust technology for the analysis of molecular interactions.
Similar articles
-
Flow cytometry for high-throughput, high-content screening.Curr Opin Chem Biol. 2004 Aug;8(4):392-8. doi: 10.1016/j.cbpa.2004.06.007. Curr Opin Chem Biol. 2004. PMID: 15288249 Review.
-
A rapid mix flow cytometer with subsecond kinetic resolution.Cytometry. 1995 Nov 1;21(3):223-9. doi: 10.1002/cyto.990210302. Cytometry. 1995. PMID: 8582244
-
Peptides, antibodies, and FRET on beads in flow cytometry: A model system using fluoresceinated and biotinylated beta-endorphin.Cytometry. 1999 Sep 1;37(1):21-31. Cytometry. 1999. PMID: 10451503
-
Detection of epitope-tagged proteins in flow cytometry: fluorescence resonance energy transfer-based assays on beads with femtomole resolution.Anal Biochem. 2001 Nov 15;298(2):151-62. doi: 10.1006/abio.2001.5363. Anal Biochem. 2001. PMID: 11700971
-
Fundamentals of flow cytometry.Mol Biotechnol. 1999 Feb;11(1):37-53. doi: 10.1007/BF02789175. Mol Biotechnol. 1999. PMID: 10367281 Review.
Cited by
-
Laboratory-Scale Simulation and Real-Time Tracking of a Microbial Contamination Event and Subsequent Shock-Chlorination in Drinking Water.Front Microbiol. 2017 Oct 4;8:1900. doi: 10.3389/fmicb.2017.01900. eCollection 2017. Front Microbiol. 2017. PMID: 29085343 Free PMC article.
-
Real-time Characterization of Antibody Binding to Receptors on Living Immune Cells.Front Immunol. 2017 Apr 24;8:455. doi: 10.3389/fimmu.2017.00455. eCollection 2017. Front Immunol. 2017. PMID: 28484455 Free PMC article.
-
FRET detection of cellular alpha4-integrin conformational activation.Biophys J. 2003 Dec;85(6):3951-62. doi: 10.1016/S0006-3495(03)74809-7. Biophys J. 2003. PMID: 14645084 Free PMC article.
-
Monitoring of dynamic microbiological processes using real-time flow cytometry.PLoS One. 2013 Nov 14;8(11):e80117. doi: 10.1371/journal.pone.0080117. eCollection 2013. PLoS One. 2013. PMID: 24244624 Free PMC article.
-
Fluorescent DNA nanotags: supramolecular fluorescent labels based on intercalating dye arrays assembled on nanostructured DNA templates.J Am Chem Soc. 2007 Feb 21;129(7):2025-34. doi: 10.1021/ja066354t. Epub 2007 Jan 26. J Am Chem Soc. 2007. PMID: 17256855 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources