Myocardial contrast echocardiography in the evaluation of viable myocardium after acute myocardial infarction
- PMID: 9662224
- DOI: 10.1016/s0002-9149(98)00050-2
Myocardial contrast echocardiography in the evaluation of viable myocardium after acute myocardial infarction
Abstract
Successfully reopening the infarct-related artery after acute myocardial infarction (MI) is currently achieved more frequently than before due to efficient therapeutic strategies, including new thrombolytic drugs and percutaneous transluminal coronary angioplasty. Successful reopening does not necessarily mean reperfusion; in fact the "no-reflow" phenomenon can occur. This phenomenon is due to functional and anatomic alterations, including microcirculation. Experimental and clinical studies have demonstrated that microvascular integrity is a fundamental prerequisite for ensuring viability after an acute MI. Often, studies have also shown that myocardial contrast echocardiography is a technique capable of detecting functional and anatomic conditions of microcirculation after ischemic reperfusion, and thus myocardial contrast echocardiography can be used for viability detection after acute MI.
Similar articles
-
Myocardial contrast echocardiography in acute myocardial infarction. Pathophysiological background and clinical applications.Eur Heart J. 1996 Mar;17(3):344-53. doi: 10.1093/oxfordjournals.eurheartj.a014867. Eur Heart J. 1996. PMID: 8737209 Review.
-
Assessing the relation between coronary reflow and myocardial reflow.Am J Cardiol. 1998 Jun 18;81(12A):8G-12G. doi: 10.1016/s0002-9149(98)00046-0. Am J Cardiol. 1998. PMID: 9662220
-
Myocardial contrast echocardiography versus dobutamine echocardiography for predicting functional recovery after acute myocardial infarction treated with primary coronary angioplasty.J Am Coll Cardiol. 1996 Dec;28(7):1677-83. doi: 10.1016/S0735-1097(96)00400-7. J Am Coll Cardiol. 1996. PMID: 8962551
-
Myocardial contrast echocardiography in acute myocardial infarction.Am J Cardiol. 2002 Nov 18;90(10A):38J-47J. doi: 10.1016/s0002-9149(02)02947-8. Am J Cardiol. 2002. PMID: 12450590 Review.
-
Analysis of microvascular integrity, contractile reserve, and myocardial viability after acute myocardial infarction by dobutamine echocardiography and myocardial contrast echocardiography.Am J Cardiol. 1996 Mar 1;77(7):441-5. doi: 10.1016/s0002-9149(97)89334-4. Am J Cardiol. 1996. PMID: 8629581 Clinical Trial.
Cited by
-
Myocardial contrast echocardiography for predicting functional recovery after acute myocardial infarction.Int J Cardiovasc Imaging. 2002 Aug;18(4):257-68. doi: 10.1023/a:1015529431982. Int J Cardiovasc Imaging. 2002. PMID: 12123318
-
Myocardial perfusion assessed by contrast echocardiography correlates with angiographic perfusion parameters in patients with a first acute myocardial infarction successfully treated with angioplasty.Can J Cardiol. 2008 Aug;24(8):633-9. doi: 10.1016/s0828-282x(08)70652-4. Can J Cardiol. 2008. PMID: 18685744 Free PMC article.
-
Perfusion assessed by real-time contrast echocardiography correlates with clinical and echocardiographic parameters in patients with first STEMI treated with PCI - 6-month follow-up.Arch Med Sci. 2010 Apr 30;6(2):176-82. doi: 10.5114/aoms.2010.13890. Arch Med Sci. 2010. PMID: 22371742 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical