T2-weighted MR imaging for hepatic hemangiomas: comparison of breath-hold and non-breath-hold turbo spin-echo pulse sequences with phased-array multicoil
- PMID: 9663280
- DOI: 10.1007/s002619900372
T2-weighted MR imaging for hepatic hemangiomas: comparison of breath-hold and non-breath-hold turbo spin-echo pulse sequences with phased-array multicoil
Abstract
Background: We compared T2-weighted and heavily T2-weighted breath-hold turbo spin-echo (TSE) sequences with T2-weighted non-breath-hold TSE sequence to evaluate hepatic hemangiomas on magnetic resonance (MR) with a phased-array multicoil.
Methods: Twenty-two patients with 27 hemangiomas were studied at 1.0-T scanner by using T2-weighted and heavily T2-weighted breath-hold TSE sequences (18 s each) and non-breath-hold T2-weighted TSE sequences with use of a phased-array multicoil. Images were quantitatively analyzed for tumor-to-liver signal-difference-to-noise ratios (SD/Ns) and tumor-to-liver signal intensity ratios (T/Ls) and qualitatively analyzed for tumor conspicuity and motion-induced image artifacts.
Results: Quantitatively, T2-weighted breath-hold TSE images showed the highest SD/Ns among the three sequences, although the differences from the heavily T2-weighted breath-hold TSE sequence and the T2-weighted non-breath-hold TSE sequence were not statistically significant (p = 0.61 and 0.06, respectively). Heavily T2-weighted breath-hold TSE images showed the highest T/Ls among the three sequences. The differences from the T2-weighted breath-hold TSE sequence and the T2-weighted non-breath-hold TSE sequence were statistically significant (p < 0.001). Qualitatively, breath-hold TSE images were superior to non-breath-hold TSE images in terms of tumor conspicuity (p < 0.01) and motion artifacts (p < 0.01).
Conclusion: T2-weighted breath-hold TSE sequence is superior to T2-weighted non-breath-hold TSE sequence in the evaluation of hepatic hemangiomas on MR with a phased-array multicoil.
Similar articles
-
Phased array breath-hold versus non-breath-hold MR imaging of focal liver lesions: a prospective comparative study.J Magn Reson Imaging. 1997 Mar-Apr;7(2):292-7. doi: 10.1002/jmri.1880070206. J Magn Reson Imaging. 1997. PMID: 9090580 Clinical Trial.
-
The value of respiratory triggered T2-weighted turbo spin-echo imaging of the liver using a phased array coil.J Magn Reson Imaging. 1998 May-Jun;8(3):655-62. doi: 10.1002/jmri.1880080321. J Magn Reson Imaging. 1998. PMID: 9626882
-
Optimal MR protocol for hepatic hemangiomas. Comparison of conventional spin-echo sequences with T2-weighted turbo spin-echo and serial gradient-echo (FLASH) sequences with gadolinium enhancement.Acta Radiol. 1997 Jul;38(4 Pt 1):565-71. doi: 10.1080/02841859709174388. Acta Radiol. 1997. PMID: 9240679
-
T2-weighted breath-hold MRI of the liver at 1.0 T: comparison of turbo spin-echo and HASTE sequences with and without fat suppression.J Magn Reson Imaging. 1998 Nov-Dec;8(6):1213-8. doi: 10.1002/jmri.1880080606. J Magn Reson Imaging. 1998. PMID: 9848731
-
Technological Advances of Magnetic Resonance Imaging in Today's Health Care Environment.Invest Radiol. 2020 Sep;55(9):531-542. doi: 10.1097/RLI.0000000000000678. Invest Radiol. 2020. PMID: 32487969 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous