The use of near-infrared spectroscopy for assessing flap viability during reconstructive surgery
- PMID: 9664881
- DOI: 10.1054/bjps.1997.0145
The use of near-infrared spectroscopy for assessing flap viability during reconstructive surgery
Abstract
The ability to assess viability of tissues by monitoring changes in oxygenation and perfusion during harvesting and following transfer of free and pedicled flaps is potentially important in reconstructive surgery. Rapid detection of a critical change in tissue oxygenation could enable earlier and more successful surgical intervention when such problems arise. In this study near infra-red spectroscopy (NIRS) was used to assess changes in tissue oxygenation, haemoglobin oxygenation and blood volume in a porcine prefabricated myocutaneous flap model in response to pedicle manipulations. As far as we are aware this is the first usage of a NIRS instrument to assess changes in oxygenation in a flap model which closely simulates the clinical situation. A myocutaneous flap was raised (n = 9 pigs), tubed and the flap circulation allowed to readjust for periods between 7 and 9 days. The pedicle vessels were then subjected to arterial (n = 9), venous (n = 12) and total occlusion (n = 6). Repeatable and reproducible patterns of change were measured in each case. Comparison of mean values indicated that the differences between arterial and venous, and venous and total occlusions were significant for all NIRS parameters. The monitor was easily able to detect two additional features: (i) the presence of venous congestion indicated by raised levels of deoxygenated haemoglobin and an increase in blood volume; and (ii) the presence and magnitude of reactive hyperaemia. In two flaps release of arterial or total occlusion did not result in the expected reactive hyperaemia associated with an increase in blood volume (oxygenated haemoglobin) suggestive of possible damage to the vascular bed. NIRS proved able to detect and distinguish between microcirculatory changes occurring as a result of arterial, venous or total vascular occlusion. We believe that NIRS provides a sensitive and reliable postoperative monitor of tissue viability following transfer of free and pedicled flaps. It can accurately identify different types of problems with the pedicle vessels. In addition its predictive capabilities would allow assessment of flaps buried deep to the skin. This monitor is excellent for surgical and intensive care unit monitoring since it is unaffected by light, portable and is extremely easy to use.
Similar articles
-
Measurements of tissue viability in transplantation.Philos Trans R Soc Lond B Biol Sci. 1997 Jun 29;352(1354):685-96. doi: 10.1098/rstb.1997.0050. Philos Trans R Soc Lond B Biol Sci. 1997. PMID: 9232856 Free PMC article.
-
Continuous postoperative monitoring of cutaneous free flaps using near infrared spectroscopy.J Plast Reconstr Aesthet Surg. 2008;61(1):71-7. doi: 10.1016/j.bjps.2007.04.003. Epub 2007 May 29. J Plast Reconstr Aesthet Surg. 2008. PMID: 17532278
-
Results of monitoring fasciocutaneous, myocutaneous, osteocutaneous and perforator flaps: 4-year experience with 166 cases.Int J Oral Maxillofac Surg. 2010 Jan;39(1):21-8. doi: 10.1016/j.ijom.2009.10.012. Epub 2009 Nov 26. Int J Oral Maxillofac Surg. 2010. PMID: 19944567
-
Near infrared spectroscopy in children at high risk of low perfusion.Curr Opin Anaesthesiol. 2010 Jun;23(3):342-7. doi: 10.1097/ACO.0b013e3283393936. Curr Opin Anaesthesiol. 2010. PMID: 20421789 Review.
-
Understanding near-infrared spectroscopy.Adv Neonatal Care. 2011 Dec;11(6):382-8. doi: 10.1097/ANC.0b013e3182337ebb. Adv Neonatal Care. 2011. PMID: 22123468 Review.
Cited by
-
Early detection and differentiation of venous and arterial occlusion in skin flaps using visible diffuse reflectance spectroscopy and autofluorescence spectroscopy.Biomed Opt Express. 2016 Jan 19;7(2):570-80. doi: 10.1364/BOE.7.000570. eCollection 2016 Feb 1. Biomed Opt Express. 2016. PMID: 26977363 Free PMC article.
-
Wearable sensors: modalities, challenges, and prospects.Lab Chip. 2018 Jan 16;18(2):217-248. doi: 10.1039/c7lc00914c. Lab Chip. 2018. PMID: 29182185 Free PMC article. Review.
-
Near-Infrared Spectroscopy (NIRS) versus Hyperspectral Imaging (HSI) to Detect Flap Failure in Reconstructive Surgery: A Systematic Review.Life (Basel). 2022 Jan 3;12(1):65. doi: 10.3390/life12010065. Life (Basel). 2022. PMID: 35054458 Free PMC article. Review.
-
Postoperative quantitative assessment of reconstructive tissue status in a cutaneous flap model using spatial frequency domain imaging.Plast Reconstr Surg. 2011 Jan;127(1):117-130. doi: 10.1097/PRS.0b013e3181f959cc. Plast Reconstr Surg. 2011. PMID: 21200206 Free PMC article.
-
Chromophore reconstruction at depth in bilayered media: a method for quantification.Biomed Opt Express. 2021 Feb 5;12(3):1279-1294. doi: 10.1364/BOE.401108. eCollection 2021 Mar 1. Biomed Opt Express. 2021. PMID: 33796353 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials