Physical examination of venous pressure: a critical review
- PMID: 9665212
- DOI: 10.1016/s0002-8703(98)70175-9
Physical examination of venous pressure: a critical review
Abstract
Objective: To explain why investigations of the measurement of central venous pressure (CVP) usually reveal a discrepancy between the clinician's estimate of CVP from physical diagnosis and supine measurement with a catheter. Data from MEDLINE search, personal files, and bibliographies of textbooks on physical diagnosis and cardiology were used.
Results: The most important reasons for this disagreement are the failure to standardize the external reference point used by the clinician to indicate "zero" venous pressure and the failure to recognize that venous pressure often depends on the position of the patient during examination. During physical examination clinicians tend to underestimate the CVP, as measured by a catheter in the same patient positioned supine, especially when the measured value is high. This occurs because the venous pressure of patients with heart failure, in contrast to that of healthy individuals, demonstrates an exaggerated postural fall when the patient is in the more upright positions that are necessary to visualize the elevated neck veins. The cause of this postural instability, increased venoconstriction from sympathetic tone, also helps explain two other physical findings of the jugular veins, the abdominojugular test, and Kussmaul's sign.
Conclusions: Clinicians should avoid making decisions about degrees of CVP elevation that are imprecise and difficult to reproduce. Instead, they should determine during physical diagnosis merely whether the CVP is elevated. Until further research is done, the best definition of elevated CVP is that of Sir Thomas Lewis-when the top of the external or internal jugular veins is >3 cm of vertical distance above the sternal angle, the CVP is abnormally high.
Comment in
-
The jugular veins: knowing enough to look.Am Heart J. 1998 Jul;136(1):6-9. doi: 10.1016/s0002-8703(98)70174-7. Am Heart J. 1998. PMID: 9665211 Review. No abstract available.
Similar articles
-
Usefulness of the external jugular vein examination in detecting abnormal central venous pressure in critically ill patients.Arch Intern Med. 2006 Oct 23;166(19):2132-7. doi: 10.1001/archinte.166.19.2132. Arch Intern Med. 2006. PMID: 17060544 Clinical Trial.
-
Human cerebral venous outflow pathway depends on posture and central venous pressure.J Physiol. 2004 Oct 1;560(Pt 1):317-27. doi: 10.1113/jphysiol.2004.070409. Epub 2004 Jul 29. J Physiol. 2004. PMID: 15284348 Free PMC article.
-
The sensitivity and specificity of ultrasound estimation of central venous pressure using the internal jugular vein.J Crit Care. 2012 Jun;27(3):315.e7-11. doi: 10.1016/j.jcrc.2011.09.008. Epub 2011 Dec 1. J Crit Care. 2012. PMID: 22137379
-
The jugular veins: knowing enough to look.Am Heart J. 1998 Jul;136(1):6-9. doi: 10.1016/s0002-8703(98)70174-7. Am Heart J. 1998. PMID: 9665211 Review. No abstract available.
-
[Measurement of central venous pressure at the jugular pulse wave].Ned Tijdschr Geneeskd. 1999 Aug 14;143(33):1692-6. Ned Tijdschr Geneeskd. 1999. PMID: 10494310 Review. Dutch.
Cited by
-
Reproducibility of point-of-care ultrasonography for central vein diameter measurement: Separating image acquisition from interpretation.J Clin Ultrasound. 2017 Oct;45(8):488-496. doi: 10.1002/jcu.22491. Epub 2017 May 8. J Clin Ultrasound. 2017. PMID: 28880382 Free PMC article.
-
Reduction in mitral regurgitation during therapy guided by measured filling pressures in the ESCAPE trial.Circ Heart Fail. 2009 May;2(3):181-8. doi: 10.1161/CIRCHEARTFAILURE.108.822999. Epub 2009 Apr 14. Circ Heart Fail. 2009. PMID: 19808338 Free PMC article. Clinical Trial.
-
Totally Implanted Port May Be an Alternative to Centrally Inserted Central Catheter for Measurement of Central Venous Pressure.J Healthc Eng. 2020 Jun 30;2020:9180856. doi: 10.1155/2020/9180856. eCollection 2020. J Healthc Eng. 2020. PMID: 32676177 Free PMC article.
-
Multimodal Strategies for the Diagnosis and Management of Refractory Congestion. An Integrated Cardiorenal Approach.Front Physiol. 2022 Jul 8;13:913580. doi: 10.3389/fphys.2022.913580. eCollection 2022. Front Physiol. 2022. PMID: 35874534 Free PMC article. Review.
-
Time-sensitive approach in the management of acute heart failure.ESC Heart Fail. 2021 Feb;8(1):204-221. doi: 10.1002/ehf2.13139. Epub 2020 Dec 9. ESC Heart Fail. 2021. PMID: 33295126 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical