Energy-selective reconstructions in X-ray computerized tomography
- PMID: 967922
- DOI: 10.1088/0031-9155/21/5/002
Energy-selective reconstructions in X-ray computerized tomography
Abstract
All X-ray computerized tomography systems that are available or proposed base their reconstructions on measurements that integrate over energy. X-ray tubes produce a broad spectrum of photon energies and a great deal of information can be derived by measuring changes in the transmitted spectrum. We show that for any material, complete energy spectral information may be summarized by a few constants which are independent of energy. A technique is presented which uses simple, low-resolution, energy spectrum measurements and conventional computerized tomography techniques to calculate these constants at every point within a cross-section of an object. For comparable accuracy, patient dose is shown to be approximately the same as that produced by conventional systems. Possible uses of energy spectral information for diagnosis are presented.
Similar articles
-
Dual-Energy Computed Tomography: Dose Reduction, Series Reduction, and Contrast Load Reduction in Dual-Energy Computed Tomography.Radiol Clin North Am. 2018 Jul;56(4):601-624. doi: 10.1016/j.rcl.2018.03.002. Radiol Clin North Am. 2018. PMID: 29936950 Review.
-
Photon counting spectral CT: improved material decomposition with K-edge-filtered x-rays.Phys Med Biol. 2012 Mar 21;57(6):1595-615. doi: 10.1088/0031-9155/57/6/1595. Epub 2012 Mar 7. Phys Med Biol. 2012. PMID: 22398007
-
Sensitivity of photon-counting based K-edge imaging in X-ray computed tomography.IEEE Trans Med Imaging. 2011 Sep;30(9):1678-90. doi: 10.1109/TMI.2011.2142188. Epub 2011 Apr 15. IEEE Trans Med Imaging. 2011. PMID: 21507770
-
Contrast in computerized transverse axial tomography of brain.Phys Med Biol. 1977 Sep;22(5):912-8. doi: 10.1088/0031-9155/22/5/010. Phys Med Biol. 1977. PMID: 909927
-
Dual-energy CT: radiation dose aspects.AJR Am J Roentgenol. 2012 Nov;199(5 Suppl):S16-25. doi: 10.2214/AJR.12.9210. AJR Am J Roentgenol. 2012. PMID: 23097163 Review.
Cited by
-
Spectral detector CT applications in advanced liver imaging.Br J Radiol. 2021 Jul 1;94(1123):20201290. doi: 10.1259/bjr.20201290. Epub 2021 May 28. Br J Radiol. 2021. PMID: 34048285 Free PMC article. Review.
-
A New Outlook on the Ability to Accumulate an Iodine Contrast Agent in Solid Lung Tumors Based on Virtual Monochromatic Images in Dual Energy Computed Tomography (DECT): Analysis in Two Phases of Contrast Enhancement.J Clin Med. 2021 Apr 26;10(9):1870. doi: 10.3390/jcm10091870. J Clin Med. 2021. PMID: 33925945 Free PMC article.
-
Photon-counting spectral basis component material decomposition for musculoskeletal radiographs.Sci Rep. 2020 Aug 17;10(1):13889. doi: 10.1038/s41598-020-70363-w. Sci Rep. 2020. PMID: 32807855 Free PMC article.
-
Deep-learning-based direct inversion for material decomposition.Med Phys. 2020 Dec;47(12):6294-6309. doi: 10.1002/mp.14523. Epub 2020 Oct 30. Med Phys. 2020. PMID: 33020942 Free PMC article.
-
Accuracy of Calcium Scoring calculated from contrast-enhanced Coronary Computed Tomography Angiography using a dual-layer spectral CT: A comparison of Calcium Scoring from real and virtual non-contrast data.PLoS One. 2018 Dec 6;13(12):e0208588. doi: 10.1371/journal.pone.0208588. eCollection 2018. PLoS One. 2018. PMID: 30521612 Free PMC article.
MeSH terms
LinkOut - more resources