Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1998 Aug;208(2):447-51.
doi: 10.1148/radiology.208.2.9680574.

Contrast-enhanced 3D MR DSA of the carotid artery bifurcation: preliminary study of comparison with unenhanced 2D and 3D time-of-flight MR angiography

Affiliations
Comparative Study

Contrast-enhanced 3D MR DSA of the carotid artery bifurcation: preliminary study of comparison with unenhanced 2D and 3D time-of-flight MR angiography

D S Willig et al. Radiology. 1998 Aug.

Abstract

Purpose: To compare the delineation of stenosis at the carotid artery bifurcation on three-dimensional (3D) magnetic resonance (MR) digital subtraction angiographic (DSA) images with that on two-dimensional (2D) and 3D time-of-flight (TOF) MR angiographic images.

Materials and methods: Twenty-six patients with 29 carotid artery bifurcations and symptoms of cerebral ischemia underwent 3D MR DSA. A time-resolved series was generated with 3D MR DSA after the bolus injection of gadodiamide. The resolution for a carotid artery examination was 0.4 x 0.4 x 1.0 mm, with volumes reconstructed at 4.5-second intervals. The 3D MR DSA images were compared with contemporaneously acquired unenhanced 2D and 3D TOF images. Two observers ranked the 2D and 3D TOF MR angiographic and 3D MR DSA images according to the following: (a) stenosis delineation, (b) internal carotid artery delineation, (c) intravascular signal intensity, and (d) diagnostic confidence.

Results: The mean ranking for diagnostic confidence was 1.10 (1 = best technique, 3 = worst technique) for 3D MR DSA. Compared with the pooled 2D TOF and 3D TOF ranks, the 3D MR DSA rank was significantly better (P < .01). Similar levels of statistical significance were found for the other criteria.

Conclusion: Three-dimensional MR DSA improves the delineation of carotid arterial stenosis by virtually eliminating saturation effects and reducing intravoxel dephasing. Surface morphology and nearly occluded vessels ("string sign") were easily identified. Confidence in identifying carotid arterial occlusions was also very high with this technique.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources