Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1998 Aug;208(2):505-9.
doi: 10.1148/radiology.208.2.9680583.

Lymphoscintigraphic identification of sentinel lymph nodes: clinical evaluation of 0.22-micron filtration of Tc-99m sulfur colloid

Affiliations

Lymphoscintigraphic identification of sentinel lymph nodes: clinical evaluation of 0.22-micron filtration of Tc-99m sulfur colloid

L R Goldfarb et al. Radiology. 1998 Aug.

Abstract

Purpose: To evaluate the use of 0.22-micron filtration of technetium-99m sulfur colloid particles in the optimization of lymphoscintigraphy.

Materials and methods: Forty-one consecutive lymphoscintigraphic studies obtained with 0.22-micron filtration of Tc-99m sulfur colloid in 41 patients (26 men, 15 women; average age, 55.4 years) and 41 consecutive studies obtained with 5.0-micron filtration in 41 patients (20 men, 21 women; average age, 54.5 years) were retrospectively, randomly reviewed. Studies were evaluated for lymphatic channel depiction and sentinel lymph node depiction. Studies included immediate flow images (obtained at 10 seconds per frame) and multiview static images obtained up to 2 hours after intradermal Tc-99m sulfur colloid injection.

Results: The number of drainage beds visualized was 52 with 5.0-micron filtration and 51 with 0.22-micron filtration (P = .570). The number of lymphatic channels visualized was 45 with 5.0-micron filtration and 75 with 0.22-micron filtration (P = .006). The number of lymph nodes visualized was 102 with 5.0-micron filtration and 123 with 0.22-micron filtration (P = .123). The number of studies judged as optimal (i.e., depicted lymphatic channels leading to sentinel nodes) was 10 with 5.0-micron filtration and 19 with 0.22-micron filtration (P = .038). The number of studies with depicted lymph nodes but no depicted lymphatic channel was 15 with 5.0-micron filtration and six with 0.22-micron filtration (P = .023).

Conclusion: The use of 0.22-micron filtration in the preparation of Tc-99m sulfur colloid substantially improves study quality and increases the diagnostic certainty in the identification of sentinel lymph nodes.

PubMed Disclaimer

Substances

LinkOut - more resources