Capillary tube resistive thermal cycling
- PMID: 9684547
- DOI: 10.1021/ac971303n
Capillary tube resistive thermal cycling
Abstract
A system that performs rapid thermal cycling of microliter and smaller liquid volumes inside glass capillary tubes that have an optically transparent thin film of indium-tin oxide (ITO) covering the exterior is described. The ITO film acts as both a heater and a temperature sensor, while cooling is accelerated with forced air. Unlike existing batch-mode thermal cycling systems, this system allows control over each sample's temperature profile. Temperature transition rates of 44 degrees Celsius per second during heating and 15 degrees Celsius per second during cooling have been achieved, allowing successful polymerase chain reaction (PCR) experiments to be performed in 20 min. Capillary external temperature can be regulated typically to within +/- 0.25 degrees Celsius, and peak temperatures more than 800 degrees Celsius have been demonstrated. Capillary internal (sample) temperatures at present are controllable typically to within 2 degrees Celsius. The resistive film can be used as a temperature sensor, and the optical transparency of the thin-film coating could permit fluorescent monitoring of the sample during thermal cycling, making this method well suited for real-time quantitative PCRs.
Similar articles
-
Performing microchannel temperature cycling reactions using reciprocating reagent shuttling along a radial temperature gradient.Analyst. 2005 Jun;130(6):931-40. doi: 10.1039/b501061f. Epub 2005 Apr 22. Analyst. 2005. PMID: 15912243
-
Bulk-micromachined submicroliter-volume PCR chip with very rapid thermal response and low power consumption.Lab Chip. 2004 Aug;4(4):401-7. doi: 10.1039/b313547k. Epub 2004 Mar 29. Lab Chip. 2004. PMID: 15269812
-
Disposable real-time microPCR device: lab-on-a-chip at a low cost.Mol Biosyst. 2006 Jun;2(6-7):292-8. doi: 10.1039/b605957k. Epub 2006 May 17. Mol Biosyst. 2006. PMID: 16880947
-
Temperature distribution effects on micro-CFPCR performance.Biomed Microdevices. 2008 Apr;10(2):141-52. doi: 10.1007/s10544-007-9119-6. Biomed Microdevices. 2008. PMID: 17896180
-
Free convective PCR: From principle study to commercial applications-A critical review.Anal Chim Acta. 2020 Apr 29;1108:177-197. doi: 10.1016/j.aca.2020.01.069. Epub 2020 Jan 31. Anal Chim Acta. 2020. PMID: 32222239 Review.
Cited by
-
Acetylated bovine serum albumin differentially inhibits polymerase chain reaction in microdevices.Biomicrofluidics. 2017 May 17;11(3):034110. doi: 10.1063/1.4983692. eCollection 2017 May. Biomicrofluidics. 2017. PMID: 28611870 Free PMC article.
-
Automated one-step DNA sequencing based on nanoliter reaction volumes and capillary electrophoresis.Nucleic Acids Res. 2000 Aug 1;28(15):E73. doi: 10.1093/nar/28.15.e73. Nucleic Acids Res. 2000. PMID: 10908366 Free PMC article.
-
Thermal sensing in fluid at the micro-nano-scales.Biomicrofluidics. 2018 Jul 2;12(4):041501. doi: 10.1063/1.5037421. eCollection 2018 Jul. Biomicrofluidics. 2018. PMID: 30867860 Free PMC article. Review.
-
ACAPELLA-1K, a capillary-based submicroliter automated fluid handling system for genome analysis.Genome Res. 2000 Jan;10(1):95-104. Genome Res. 2000. PMID: 10645954 Free PMC article.
-
Reduction of water evaporation in polymerase chain reaction microfluidic devices based on oscillating-flow.Biomicrofluidics. 2010 Sep 1;4(3):036502. doi: 10.1063/1.3481776. Biomicrofluidics. 2010. PMID: 20877657 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources